Effects of posture on peripheral vascular responses to lower body positive pressure

Abstract: We tested the hypothesis that peripheral vascular responses (in the lower and upper limbs) to application of lower body positive pressure (LBPP) are dependent on the posture of the subjects. We measured heart rate, stroke volume, mean arterial pressure, leg and forearm blood flow (using the Doppler ultrasound technique), and leg (LVC) and forearm (FVC) vascular conductance in 11 subjects (9 men, 2 women) without and with LBPP (25 and 50 mmHg) in supine and upright postures. Mean arterial pressure increased in … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
21
1
2

Year Published

2011
2011
2023
2023

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 26 publications
(27 citation statements)
references
References 28 publications
1
21
1
2
Order By: Relevance
“…CO and LBF were measured using Doppler ultrasound as previously described in detail (22,23,43). Briefly, a Doppler ultrasound system (HDI 3500, Philips) equipped with a hand-held transducer probe (model D2 CW) with an operating frequency of 2 MHz was used to measure aortic blood velocity in the suprasternal notch.…”
Section: Subjectsmentioning
confidence: 99%
See 1 more Smart Citation
“…CO and LBF were measured using Doppler ultrasound as previously described in detail (22,23,43). Briefly, a Doppler ultrasound system (HDI 3500, Philips) equipped with a hand-held transducer probe (model D2 CW) with an operating frequency of 2 MHz was used to measure aortic blood velocity in the suprasternal notch.…”
Section: Subjectsmentioning
confidence: 99%
“…Aortic and common femoral artery diameters were calculated using the above formula, and cross-sectional areas (CSAs; in cm 2 ) were estimated as follows: CSA ϭ (Dm/10/2) 2 ϫ . Instantaneous mean blood velocity (MBV) was continuously estimated using a computer program developed with the aid of LabView (version 6.0, National Instruments), as previously described in detail (23,43). Our system collects MBV at 100 Hz together with analog signals representing the ECG, blood pressure waveform, and respiratory flow.…”
Section: Subjectsmentioning
confidence: 99%
“…We measured FBF using Doppler ultrasound as previously described (12,19,24). Briefly, a Doppler ultrasound system (HDI 5000; ATL Ultrasound) equipped with a hand-held transducer probe (model L12-5) with an operating frequency of 6 MHz was used to simultaneously measure two-dimensional brachial artery diameter and mean blood velocity (MBV).…”
Section: Subjectsmentioning
confidence: 99%
“…We calculated Dm for each minute as the mean Dm value from 20 consecutive beats during the previous 30 s. The cross-sectional area of the brachial artery (CSA) was estimated using the representative D m as CSA ϭ (Dm/10/2) 2 ·. MBV was continuously estimated by means of a computer program developed with the aid of LabVIEW (version 6.0; National Instruments), as described in detail elsewhere (12,24). Our system collects MBV at 100 Hz together with the analog signals representing the ECG and blood pressure waveform.…”
Section: Subjectsmentioning
confidence: 99%
“…We evaluated SV using Doppler ultrasound (27). A Doppler ultrasound system (Echo Doppler; HDI 3500; Atl/Philips Ultrasound, Bothwell, WA), equipped with a hand-held transducer probe (operating frequency: 2 MHz), was used to measure ascending aortic blood velocity.…”
Section: Measurementsmentioning
confidence: 99%