2006
DOI: 10.1109/tdei.2006.1624276
|View full text |Cite
|
Sign up to set email alerts
|

Effects of nano- and micro-filler mixture on electrical insulation properties of epoxy based composites

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
88
0
3

Year Published

2013
2013
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 213 publications
(95 citation statements)
references
References 10 publications
4
88
0
3
Order By: Relevance
“…Here the dielectric measurements were carried out by Impedance spectroscopy (LCR HITESTER 3532-50) measuring instrument. It was also an experimental method of characterizing electrochemical systems [9][10][11][12]. This technique was also used to measure the impedance of a system over a range of frequencies, and the frequency response of the system including the energy storage and dissipation properties.…”
Section: Dielectric Spectroscopic Results Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…Here the dielectric measurements were carried out by Impedance spectroscopy (LCR HITESTER 3532-50) measuring instrument. It was also an experimental method of characterizing electrochemical systems [9][10][11][12]. This technique was also used to measure the impedance of a system over a range of frequencies, and the frequency response of the system including the energy storage and dissipation properties.…”
Section: Dielectric Spectroscopic Results Analysismentioning
confidence: 99%
“…Process of tracking the specimen. In SEM, the image may be produced in a number of ways from variations in the intensity of secondary electrons back-scattered from the specimen through to Xray emission produced by inelastic collisions of the primary beam with bound electrons in the specimen [8][9][10]. From the analyzed SEM image the particles were in the form of nano metric range varies for one area to other.…”
Section: Characterization Of Zirconia Nano Fillermentioning
confidence: 99%
See 1 more Smart Citation
“…Based on this, Tcure was determined to be 170 °C for all the composite samples. A low CTE is desired to achieve dimensional stability [17]. The dimensional change curves for the epoxy composites with various amounts of the HNT and Zr/HNT fillers are shown in Figure 7.…”
Section: Characterization Of Zr/hnt Fillermentioning
confidence: 99%
“…Visible light could penetrate such a thin sample and thus, trees were observed using optical microscopy. Others have sliced the sample near the needle tip and optically imaged the treeing area [7]. A different situation is encountered when imaging electrical trees in nano-filled materials.…”
Section: Introductionmentioning
confidence: 99%