2007
DOI: 10.1002/mus.20718
|View full text |Cite
|
Sign up to set email alerts
|

Effects of intramuscular needle position on motor unit action potential metrics

Abstract: It is unclear whether there are clinically significant differences in amplitude, duration, and numbers of turns and phases if an electromyographic (EMG) study is performed near to, or far from, the end-plate zone. The effects of temporal dispersion of arriving muscle-fiber action potentials on quantitative motor unit action potential (MUAP) metrics were assessed in simulated and biologic muscles. Two muscle simulation models were studied with electrode recording positions near the motor end-plate zone and 50-7… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0
2

Year Published

2009
2009
2020
2020

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 13 publications
0
1
0
2
Order By: Relevance
“…In this study, we did not investigate the amplitude of the evoked potentials elicited by electrical stimulation of the recurrent laryngeal nerve because we recorded the evoked potentials from the thyroarytenoid muscle using the monopolar needle, and this caused a dramatic variation in the response, with slight changes in the position of electrodes relative to each motor unit distribution within a muscle, especially near the endplate zones . Therefore, the amplitude of the evoked potentials in the recurrent laryngeal nerve, as assessed by the monopolar needle, does not represent the characteristics of the evoked potentials in the recurrent laryngeal nerve.…”
Section: Discussionmentioning
confidence: 99%
“…In this study, we did not investigate the amplitude of the evoked potentials elicited by electrical stimulation of the recurrent laryngeal nerve because we recorded the evoked potentials from the thyroarytenoid muscle using the monopolar needle, and this caused a dramatic variation in the response, with slight changes in the position of electrodes relative to each motor unit distribution within a muscle, especially near the endplate zones . Therefore, the amplitude of the evoked potentials in the recurrent laryngeal nerve, as assessed by the monopolar needle, does not represent the characteristics of the evoked potentials in the recurrent laryngeal nerve.…”
Section: Discussionmentioning
confidence: 99%
“…Biri 90 µm'lik sabit çap değerine diğeri de 20 µm ile 85 µm arasında çap değerleri değişen 2 kas lifinden kas sinir kavşağının yakınından ve tendonun yakınından kaydedilen sinyallere ait olan ilk ve son minimum genliklerinin süreleri ve bu sürelerle ilişkili zamansal yayılım değerleri Tablo [13]. Günlük EMG pratiğinde kullanılan konsantrik iğne elektrot aracılı bu çalışmalar, MÜAP parametrelerinin kavşaktan uzaklaştıkça değiştiğini ortaya koymuşlardır.…”
Section: Tartışma Ve Sonuçlarunclassified
“…Los parámetros definidos para cuantificar dichas dimensiones deberían mostrarse robustos y ofrecer estimaciones fiables aunque varíen las condiciones de registro. La amplitud y el área están relacionadas con el número de FMs de la UM presentes en el radio de captación del electrodo, pero muestran una amplia variabilidad dependiendo de la distancia del electrodo a las FMs 42 . Para superar esta limitación se intenta formular parámetros e índices que expresen el número de FMs de la UM con independencia de la distancia entre el electrodo y las FMs y que tengan, por tanto, mayor capacidad discriminativa entre la normalidad y la patología.…”
Section: Definición De Nuevos Parámetrosunclassified