2017
DOI: 10.1088/1361-6560/aa54c7
|View full text |Cite
|
Sign up to set email alerts
|

Effects off-number on the histotripsy intrinsic threshold and cavitation bubble cloud behavior

Abstract: Histotripsy is an ultrasound ablation method that depends on the initiation of a cavitation bubble cloud to fractionate soft tissue. Although previous work has provided significant insight into the process of intrinsic threshold histotripsy, the majority of these studies have used highly focused (i.e. f-number<0.6) transducers. In this study, we investigate the effects of f-number on the histotripsy intrinsic threshold and cavitation bubble cloud behavior using a 500 kHz array transducer, with the effective f-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
63
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 51 publications
(67 citation statements)
references
References 36 publications
4
63
0
Order By: Relevance
“…An understanding of the reasons for this can be approached by considering the pressure steering profiles and the geometric focal pressure for the 250 and 500 kHz array. As the lesion size correlates well with the dimensions of the focus above the intrinsic threshold (Vlaisavljevich et al 2017) and the 1D beam profiles (Fig. 2) show a much larger focal region at 250 kHz, the focal spacing was made proportional to the frequency of the array.…”
Section: Discussionmentioning
confidence: 70%
“…An understanding of the reasons for this can be approached by considering the pressure steering profiles and the geometric focal pressure for the 250 and 500 kHz array. As the lesion size correlates well with the dimensions of the focus above the intrinsic threshold (Vlaisavljevich et al 2017) and the 1D beam profiles (Fig. 2) show a much larger focal region at 250 kHz, the focal spacing was made proportional to the frequency of the array.…”
Section: Discussionmentioning
confidence: 70%
“…The total focal volume, and therefore the total number of insonated nuclei, will be dictated by the frequency and transducer geometry. No significant changes have been observed in the intrinsic cavitation threshold for 500-kHz transducers with f-numbers between 0.5 and 0.9 (Vlaisavljevich et al 2017a).…”
Section: Dependence Of Intrinsic Threshold On Histotripsy Insonation mentioning
confidence: 83%
“…That is, bubbles can be nucleated before the onset of strong non-linearities for intrinsic threshold pulses. The bubble cloud density within the focal regions is also significantly increased for low f-number sources (Vlaisavljevich et al 2017a).…”
Section: Intrinsic-threshold Histotripsymentioning
confidence: 95%
See 2 more Smart Citations