2021
DOI: 10.1016/j.seta.2021.101083
|View full text |Cite
|
Sign up to set email alerts
|

Effects of helical absorber tube on the energy and exergy analysis of parabolic solar trough collector – A computational analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 23 publications
(9 citation statements)
references
References 46 publications
0
9
0
Order By: Relevance
“…A total of three compositions for nanoparticles (Al 2 O 3 25%-CuO 75%, Al 2 O 3 50%-CuO 50%, and Al 2 O 3 75%-CuO 25%) in water are analyzed with the solar intensity of 708 W/m 2 . 30 The temperature at the flow's inlet is set between 298 and 308 K. 30 At an inlet temperature of 308 K, the entire system performs better. As a result of the study's findings, the discussion follows is predicated on a 308 K inlet temperature.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…A total of three compositions for nanoparticles (Al 2 O 3 25%-CuO 75%, Al 2 O 3 50%-CuO 50%, and Al 2 O 3 75%-CuO 25%) in water are analyzed with the solar intensity of 708 W/m 2 . 30 The temperature at the flow's inlet is set between 298 and 308 K. 30 At an inlet temperature of 308 K, the entire system performs better. As a result of the study's findings, the discussion follows is predicated on a 308 K inlet temperature.…”
Section: Resultsmentioning
confidence: 99%
“…For varied ratios with a 1% volume concentration in water, Al 2 O 3 ‐CuO is used as the working medium. A total of three compositions for nanoparticles (Al 2 O 3 25%‐CuO 75%, Al 2 O 3 50%‐CuO 50%, and Al 2 O 3 75%‐CuO 25%) in water are analyzed with the solar intensity of 708 W/m 2 30 . The temperature at the flow's inlet is set between 298 and 308 K 30 .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Balls of spherical shape and elliptical inserted for diameter as well as the major diameter of 48 mm are considered respectively. The reason is that in the earlier studies with these kinds of inserts, the best outcomes are noted with 48mm of maximum diameter [2,25]. For the elliptical inserts, two values of minor diameter 12mm and 24mm are being simulated.…”
Section: Physical Modelmentioning
confidence: 99%
“…This study showed an improvement of 0.22% and 0.52% for exergy efficiency and overall efficiency, respectively. Instead of taking a conventional receiver, a structured helical receiver for the LS-2 model of PTC in the case of water heating was examined analytically by Chakraborty et al [25]. This investigation showed that thermal efficiency improved by 4%-10% more with this type of receiver than with the smooth receiver tube of PTC.…”