2015
DOI: 10.1016/j.acra.2014.08.009
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Guided Random Sampling of TCCs on Blood Flow Values in CT Perfusion Studies of Lung Tumors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
10

Relationship

5
5

Authors

Journals

citations
Cited by 24 publications
(9 citation statements)
references
References 31 publications
0
9
0
Order By: Relevance
“…Then, for each lesion, the radiologists performed a 3D alignment according to the procedure described in [ 29 ]. In order to obtain the TCCs relative to each voxel, the values of the temporal sequence were fitted using the sigmoid-shape model, arising from the Hill Equation [ 30 ], and the random sampling method described in [ 31 ]. The curve fitting is achieved employing an in-house fitting algorithm based on the nonlinear, least squares, Levenberg-Marquardt minimization algorithm (lsqcurvefit, MATLAB © ; MathWorks, Natick, MA, USA).…”
Section: Methodsmentioning
confidence: 99%
“…Then, for each lesion, the radiologists performed a 3D alignment according to the procedure described in [ 29 ]. In order to obtain the TCCs relative to each voxel, the values of the temporal sequence were fitted using the sigmoid-shape model, arising from the Hill Equation [ 30 ], and the random sampling method described in [ 31 ]. The curve fitting is achieved employing an in-house fitting algorithm based on the nonlinear, least squares, Levenberg-Marquardt minimization algorithm (lsqcurvefit, MATLAB © ; MathWorks, Natick, MA, USA).…”
Section: Methodsmentioning
confidence: 99%
“…The technique involves fitting each position trace with a sigmoid (four parameters: position offset, time offset, slope, and amplitude) (Waitzman et al, 1991). We used a RANSAC algorithm (Gibaldi et al, 2015) to find the best sigmoid using data from 50 ms before the preliminary start point to 50 ms after the preliminary endpoint. We defined start points and endpoints, respectively, as the 2% and 98% of the sigmoid.…”
Section: Experiments 1: Oculomotor Horoptermentioning
confidence: 99%
“…RFs were extracted from PCa ROIs, from both ADC and DWI b2000 sequences. For each slice with lesion, seven first-order RFs, including mean, median, skewness, kurtosis, interquartile range, coefficient of variation [ 22 ] and entropy, were computed on a local tissue patch based on the method proposed in [ 22 , 23 ], in order to account for the small changes of tissue heterogeneity occurring between neighbor voxels. The smallest informative tissue unit for radiomic analysis was chosen to be approximately 1 cm 2 .…”
Section: Methodsmentioning
confidence: 99%