2010
DOI: 10.1109/tec.2010.2047042
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Fan Blade Forward-Swept and Inclined Amounts in Electric Motors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
4
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…The axial arrangement is the most efficient, while the radial arrangement is common for small-size electric motor [41,42]. Numeric modeling has been intensively used to improve the blade profile design of the external fan in order to reduce noise and increase the cooling air speed at the motor's surface [31,55,56,59,61,89,134].…”
Section: The Air Cooling Systemmentioning
confidence: 99%
“…The axial arrangement is the most efficient, while the radial arrangement is common for small-size electric motor [41,42]. Numeric modeling has been intensively used to improve the blade profile design of the external fan in order to reduce noise and increase the cooling air speed at the motor's surface [31,55,56,59,61,89,134].…”
Section: The Air Cooling Systemmentioning
confidence: 99%
“…The bending of the fan characteristic curve is due to the energy losses, and can be improved by optimizing the aerodynamic structure of the blades. A new kind of axial fan with forward-swept and inclined blades is employed in [37][38][39] to reduce the ventilation resistance inside an electric motor, as is illustrated in Fig. 5.…”
Section: ) Forced Airmentioning
confidence: 99%
“…One of the major challenges associated with fan cooling is the emission of acoustic noise, especially at a high speed fan operation. Several noise mitigation methods have been proposed by the literature: a) using forward-swept inclined fans [37,38]; b) using a better aero-foil shape blade crosssection [41]; c) using inlet bell-mouth entry [42]; d) using composite materials for blades [42]; e) reducing the number of blades [41,42]; f) using irregular-pitch-blade fan [30,42,43]; g) using a mixed flow (both axial and radial) fan [41].…”
Section: ) Forced Airmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition to the relative low cooling capacity of the forced convective airflow, the emission of acoustic noise from the fan was a major problem. Several attempts for mitigating the fan noise, especially at high speeds, were proposed by using the forward-swept blades [19], the aero-foil shaped blades [20], the bell-mouth fan entry, the irregular-pitch-blade fan and/or reducing the blade number [21]. With the forced convective liquid cooling schemes, the housing jackets embedded with a variety of coolant channels were commonly adopted.…”
Section: Introductionmentioning
confidence: 99%