2004
DOI: 10.1111/j.1440-1843.2004.00631.x
|View full text |Cite
|
Sign up to set email alerts
|

Effects of different anti‐asthmatic agents on induced sputum and eosinophil cationic protein in mild asthmatics

Abstract: All three treatments resulted in significant decreases in sputum total cell counts and eosinophil percentage, but the decrease in sputum ECP level was only seen in the groups treated with budesonide and zafirlukast. These results suggest that although all three treatments are considered as first-line treatments in most consensuses, theophylline seems to have less of an inhibitory effect on eosinophil activation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
26
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(26 citation statements)
references
References 30 publications
0
26
0
Order By: Relevance
“…Three thousand seven hundred and twenty‐eight patients from 16 studies (12, 14–16, 18–24, 26–28, 31, 32) were considered for this analysis (1833 treated with ICS, 1895 treated with LTRA). ICS was significantly superior to LTRA therapy in improving FEV 1 in absolute value (Fig.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Three thousand seven hundred and twenty‐eight patients from 16 studies (12, 14–16, 18–24, 26–28, 31, 32) were considered for this analysis (1833 treated with ICS, 1895 treated with LTRA). ICS was significantly superior to LTRA therapy in improving FEV 1 in absolute value (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Sixty patients from two studies (12,19) were considered for this analysis (29 treated with ICS, 31 treated with LTRA). ICS was similar to LTRA therapy in decreasing percentage of peripheral blood eosinophils ( Fig.…”
Section: Percentage Changes From Baseline In Peripheral Blood Eosinopmentioning
confidence: 99%
See 1 more Smart Citation
“…Evaluation and continued monitoring of eosinophil and ECP may be a way to assess efficacy of asthma therapy and airway inflammation in children with allergic asthma [58]. Both leukotriene receptor antagonists and inhaled corticosteroids have been associated with a reduction in sputum ECP levels in patients with mild to moderate persistent asthma [59,60]. A response of serum ECP levels to glucocorticoid treatment has also been observed [61].…”
Section: Eosinophil Cationic Proteinmentioning
confidence: 99%
“…No unpublished studies met the criteria for inclusion in this review. The 37 articles were assessed for risk of bias [11], and six articles had a low risk of bias [43,57,70,[75][76][77], 17 had an unclear risk of bias [42,46,47,52,53,55,56,58,61,[63][64][65][66]69,[71][72][73], and 14 had a high risk of bias [41,44,45,[48][49][50][51]54,59,60,62,67,68,74]. Detailed results for the risk of bias assessment of each article can be found in Supporting Information S1.…”
Section: Resultsmentioning
confidence: 99%