Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies 2017
DOI: 10.5220/0006154400320037
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Configuration and Dimension of Concentric Ring Electrodes in EEnG Recording Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2018
2018
2018
2018

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…The use of the developed multi-CRE for non-invasive EEnG recording permitted the study of the influence of the factors affecting recording conditions on different signal quality parameters of this specific application. In a preliminary work, we computed a reduced set of parameters (%DF TFSW, PR RESP , PR LF and %DF SW ) for different ring sizes and configurations with multi-CRE in below navel position and adhesive material [ 30 ]. In the present work, factors such as the recording position and the type of adhesive material have also been considered, and its effects has been studied for a more comprehensive set of 10 parameters.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The use of the developed multi-CRE for non-invasive EEnG recording permitted the study of the influence of the factors affecting recording conditions on different signal quality parameters of this specific application. In a preliminary work, we computed a reduced set of parameters (%DF TFSW, PR RESP , PR LF and %DF SW ) for different ring sizes and configurations with multi-CRE in below navel position and adhesive material [ 30 ]. In the present work, factors such as the recording position and the type of adhesive material have also been considered, and its effects has been studied for a more comprehensive set of 10 parameters.…”
Section: Discussionmentioning
confidence: 99%
“…Since all the rings were 2 mm wide, this behavior could be due to the larger skin-to-electrode contact area and the associated reduced contact impedance. On the other hand, the influence of respiratory interference on the EEnG record is greater with increasing ring size, probably because the possible movements of the central disk and the outer ring caused by respiration are less temporarily synchronized by the larger outer ring [ 30 ]. The best results in terms of intestinal SW identification and global signal quality were obtained with the 30 mm outer diameter ring, which manages to balance the previously indicated factors.…”
Section: Discussionmentioning
confidence: 99%