2022
DOI: 10.1016/j.petrol.2021.109555
|View full text |Cite
|
Sign up to set email alerts
|

Effects of cleaning process using toluene and acetone on water-wet-quartz/CO2 and oil-wet-quartz/CO2 wettability

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
20
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 28 publications
(21 citation statements)
references
References 70 publications
1
20
0
Order By: Relevance
“…Solvents (toluene and alcohol) were used to clean the core plugs and prepare them for the measurements. Toluene was used to clean any residual oil in the rocks while alcohol was used to remove precipitated salt within the rock's pores (Al-Yaseri et al 2022;Isah et al 2021a, b).…”
Section: Samples Preparationmentioning
confidence: 99%
“…Solvents (toluene and alcohol) were used to clean the core plugs and prepare them for the measurements. Toluene was used to clean any residual oil in the rocks while alcohol was used to remove precipitated salt within the rock's pores (Al-Yaseri et al 2022;Isah et al 2021a, b).…”
Section: Samples Preparationmentioning
confidence: 99%
“…A total of five observation points with three repeats were obtained for the electrical resistivity measurements. The error in contact angle measurements was ±3° . The average standard deviation for the resistivity index (RI), rock resistivity ( R t ), and formation factor ( F ) were 5.34, 8.29 Ω·m, and 16.06, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…The error in contact angle measurements was ±3°. 77 The average standard deviation for the resistivity index (RI), rock resistivity (R t ), and formation factor (F) .06, respectively. We used the twoelectrode (silver chloride-coated silver electrodes) configuration.…”
Section: Sample Preparation Two Cylindrical Homogeneousmentioning
confidence: 99%
“…First, the shale core specimens were trimmed into specific dimensions (1 cm width × 1.5 cm length × 1 cm height) that can conveniently fit into the moving table, and the cut shale specimens were polished to achieve an even surface. Acetone was used to clean the shale surfaces . Then, the shale substrate was positioned on the moving table in the view cell of the Krüss drop shape analyzer 100 (Eurotechnica, Germany), and temperature was increased gradually at 10 °C until the desired temperature was reached.…”
Section: Methodsmentioning
confidence: 99%
“…Acetone was used to clean the shale surfaces. 51 Then, the shale substrate was positioned on the moving table in the view cell of the Kruss drop shape analyzer 100 (Eurotechnica, Germany), and temperature was increased gradually at 10 °C until the desired temperature was reached.…”
mentioning
confidence: 99%