1988
DOI: 10.1111/j.1476-5381.1988.tb11462.x
|View full text |Cite
|
Sign up to set email alerts
|

Effects of bepridil on ventricular depolarization and repolarization of rabbit isolated hearts with particular reference to its possible proarrhythmic properties

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
8
0

Year Published

1989
1989
2009
2009

Publication Types

Select...
7
1
1

Relationship

2
7

Authors

Journals

citations
Cited by 19 publications
(9 citation statements)
references
References 24 publications
(26 reference statements)
1
8
0
Order By: Relevance
“…34 In line with this regional difference in the APD prolongation on the apexbase axis, the present study on the human heart has demonstrated that bepridil causes a greater prolongation of the MAPDs in the RVOT than in the RVA. In voltage-clamp experiments on rabbit LV myocytes, Chen et al showed higher IKr and lower IKs densities in the apex than those in the base.…”
Section: Inhomogeneous Mapd Prolongation By Bepridilsupporting
confidence: 81%
“…34 In line with this regional difference in the APD prolongation on the apexbase axis, the present study on the human heart has demonstrated that bepridil causes a greater prolongation of the MAPDs in the RVOT than in the RVA. In voltage-clamp experiments on rabbit LV myocytes, Chen et al showed higher IKr and lower IKs densities in the apex than those in the base.…”
Section: Inhomogeneous Mapd Prolongation By Bepridilsupporting
confidence: 81%
“…A schematic diagram of a typical preparation is shown in Fig. 1 (Veenstra, Joyner & Rawling, 1984;Osaka, Kodama, Toyama & Yamada, 1988 Fig. 1A, the time of activation of other sites with respect to the time of initiation of the action potential at the primary pacemaker site is shown as a series of isochrones (dashed lines) at 5 ms intervals.…”
Section: Methods Preparationmentioning
confidence: 99%
“…We recorded nique is, however, limited by large far-field potentials of extracellular potentials from the endocardial surface of atrial muscle close to the SA node [8,9]. isolated rabbit right atria including the whole SA node using custom-made modified bipolar electrodes [10,11], since the proximity of the indifferent and active poles of time. Each pair of MBEs was positioned using a calibrated the electrodes is expected to provide a high level of X,Y,Z-micromanipulator with 0.1 mm precision.…”
Section: Introductionmentioning
confidence: 99%