2001
DOI: 10.1093/clinchem/47.6.1109
|View full text |Cite
|
Sign up to set email alerts
|

Effects of Anticoagulants and Contemporary Blood Collection Containers on Aluminum, Copper, and Zinc Results

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
14
0
1

Year Published

2012
2012
2021
2021

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(18 citation statements)
references
References 3 publications
3
14
0
1
Order By: Relevance
“…This could be in part due to the different collection methodologies of the cohorts, with the SCOPE cohort using heparinised tubes for plasma collection, whilst the Lyell McEwin cohort used EDTA collection vessels. Previous studies have highlighted that different anticoagulants can significantly impact the concentrations of elements available in plasma; haemolysis, particularly with Fe, of these samples has also shown to affect the concentrations [28,29]. As stated previously, Se concentrations collected in the Lyell McEwin cohort were markedly decreased when compared with those in established reference ranges; however, the concentrations published in the SCOPE study fall within these ranges albeit on the lower end (SCOPE: 71.94 ± 11.06 μg/L (minimum = 42.96 μg/L, maximum = 108.98 μg/L), reference range: 70-150 μg/L) [9,21].…”
Section: Discussionmentioning
confidence: 99%
“…This could be in part due to the different collection methodologies of the cohorts, with the SCOPE cohort using heparinised tubes for plasma collection, whilst the Lyell McEwin cohort used EDTA collection vessels. Previous studies have highlighted that different anticoagulants can significantly impact the concentrations of elements available in plasma; haemolysis, particularly with Fe, of these samples has also shown to affect the concentrations [28,29]. As stated previously, Se concentrations collected in the Lyell McEwin cohort were markedly decreased when compared with those in established reference ranges; however, the concentrations published in the SCOPE study fall within these ranges albeit on the lower end (SCOPE: 71.94 ± 11.06 μg/L (minimum = 42.96 μg/L, maximum = 108.98 μg/L), reference range: 70-150 μg/L) [9,21].…”
Section: Discussionmentioning
confidence: 99%
“…On the other hand, in the study of Frank et. al., [12] in which the Zn level in serum and several types of plasma samples were compared, significantly higher Zn level was detected in EDTA plasma. C Zn / mg mL -1 The higher level of Zn in EDTA plasma was related to the contamination of collection container / anticoagulant with Zn.…”
Section: Influence Of Anticoagulants On Zn Level Detected In Plasmamentioning
confidence: 99%
“…al. [12] however, citrate plasma was not included in that study. Therefore, in this study, the Zn level detected in EDTA, heparin and citrate plasma samples, was compared to the Zn level detected in serum samples.…”
Section: Influence Of Anticoagulants On Zn Level Detected In Plasmamentioning
confidence: 99%
See 1 more Smart Citation
“…Sedikit kekurangan dalam penanganan sampel sejak pengambilan sampai analisis dapat turut serta memengaruhi hasil. 18,19 Sarana pemeriksaan kadar seng plasma yang tersedia di laboratorium rumah sakit tempat penelitian berlangsung dapat meminimalkan perubahan kadar seng plasma yang terjadi, karena dapat segera dilakukan pemeriksaan. Persediaan seng tubuh sensitif terhadap jumlah seng yang diabsorpsi dari makanan, sehingga makanan yang dimakan subjek sangat memengaruhi kadar seng plasmanya.…”
Section: Pembahasanunclassified