Effectiveness of intracavitary electrocardiogram-guided peripherally inserted central catheter tip placement in premature infants: a multicentre pre-post intervention study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
14
0
9

Year Published

2020
2020
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(25 citation statements)
references
References 34 publications
2
14
0
9
Order By: Relevance
“…Phlebitis was a common vascular access complication, and its incidence in E/VLBW infants in this study was 7.71%. This is similar to another study that reported a 12% incidence in low-birthweight infants ( 9 ) but much higher than the rate of 0.6%–3.5% reported in the full-term neonatal population ( 10 , 11 ). This can be explained as phlebitis is mainly caused by mechanical stimulation ( 12 ); thus, it would be preferable to use 1 Fr catheters to reduce the risk of mechanical stimulation when the vein is small, especially the femoral vein.…”
Section: Discussionsupporting
confidence: 90%
“…Phlebitis was a common vascular access complication, and its incidence in E/VLBW infants in this study was 7.71%. This is similar to another study that reported a 12% incidence in low-birthweight infants ( 9 ) but much higher than the rate of 0.6%–3.5% reported in the full-term neonatal population ( 10 , 11 ). This can be explained as phlebitis is mainly caused by mechanical stimulation ( 12 ); thus, it would be preferable to use 1 Fr catheters to reduce the risk of mechanical stimulation when the vein is small, especially the femoral vein.…”
Section: Discussionsupporting
confidence: 90%
“…Um recurso a beiraleito que pode contribuir para o posicionamento correto da ponta durante a inserção do cateter são os dispositivos de eletronavegação. Essa tecnologia ajuda a deixar a ponta bastante próxima à área da junção cavo-atrial através do reconhecimento da maior amplitude da onda P no monitor cardíaco, com alta eficácia 10 , inclusive em recémnascidos.…”
Section: Discussionunclassified
“…12,13 The authors performed a jet injection of 0.9% Saline and checked the result using the intracavitary electrocardiography method of tip location. [14][15][16][17][18] After the appearance of high-amplitude P waves, chest radiograph showed that the PICC was re-positioned into the vena cava in five cases. Considering the possibility of re-malposition, the intracavitary electrocardiogram positioning technology was used to confirm the position of the catheter tip before using of vesicant drugs.…”
Section: Management Of Secondary Malposition Of Picc Into Azygos Veinsmentioning