2012
DOI: 10.1118/1.4738966
|View full text |Cite
|
Sign up to set email alerts
|

Effectiveness of external respiratory surrogates for in vivo liver motion estimation

Abstract: Purpose: Due to low frame rate of MRI and high radiation damage from fluoroscopy and CT, liver motion estimation using external respiratory surrogate signals seems to be a better approach to track liver motion in real-time for liver tumor treatments in radiotherapy and thermotherapy. This work proposes a liver motion estimation method based on external respiratory surrogate signals. Animal experiments are also conducted to investigate related issues, such as the sensor arrangement, multisensor fusion, and the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 41 publications
0
4
0
Order By: Relevance
“…The changes in lung and ventilation mechanics under pneumoperitoneum are well documented, including basal atelectasis, compression of the lung basis, and a raised diaphragmatic dome [ 49 52 ]. A potential explanation for this is that the physiological and mechanical changes during pneumoperitoneum cause this significant decrease in liver motion due to decreased diaphragmatic motion, which has been shown to be highly correlated to liver motion [ 53 ]. Earlier studies report on liver motion due to introduction of pneumoperitoneum.…”
Section: Discussionmentioning
confidence: 99%
“…The changes in lung and ventilation mechanics under pneumoperitoneum are well documented, including basal atelectasis, compression of the lung basis, and a raised diaphragmatic dome [ 49 52 ]. A potential explanation for this is that the physiological and mechanical changes during pneumoperitoneum cause this significant decrease in liver motion due to decreased diaphragmatic motion, which has been shown to be highly correlated to liver motion [ 53 ]. Earlier studies report on liver motion due to introduction of pneumoperitoneum.…”
Section: Discussionmentioning
confidence: 99%
“…There have been several approaches to estimating the patient motion during thermal ablations using additional imaging scanners or sensors including ultrasound imaging [37], surrogate sensors [38], and ultrasound sensors [39]. Those approaches enable compensation of the patient motion with a temporal resolution higher than the MR scan.…”
Section: Discussionmentioning
confidence: 99%
“…16 Moreover, marker migration is possible and leads to tumor localization errors. Noninvasive surrogates such as breathing signals from surface imaging can also be used for real-time tumor tracking, [17][18][19][20] but the motion correlation between the external markers and internal target motions may not be perfect 21 and is usually patient-specific. Markerless tracking using online magnetic resonance imaging has been used to track tumors.…”
Section: Introductionmentioning