2019
DOI: 10.1111/jce.13994
|View full text |Cite
|
Sign up to set email alerts
|

Effectiveness of dual external direct current cardioversion for initial cardioversion in atrial fibrillation

Abstract: Introduction Dual external direct current cardioversion (dual‐DCCV) is a rhythm control strategy for persistent atrial fibrillation (AF), involving simultaneous delivery of two shocks from two defibrillators. The long‐term effectiveness of this approach has not been studied in the biphasic cardioversion era. Methods Seventy‐seven consecutive patients at a single center were identified to receive dual‐DCCV at the time of their initial cardioversion for AF, when maximum output standard external direct current ca… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 23 publications
0
6
0
Order By: Relevance
“…Dual external cardioversion using biphasic shock is a safe and effective strategy in patients with large body habitus. 7 , 27 In our study, the mean BMI in a patient that required the use of two simultaneous defibrillators was 56.2 ± 9.51 while the remaining patients in Group B had a mean BMI of 35.9 ± 9.81 ( P < 0.0001).…”
Section: Discussionmentioning
confidence: 49%
“…Dual external cardioversion using biphasic shock is a safe and effective strategy in patients with large body habitus. 7 , 27 In our study, the mean BMI in a patient that required the use of two simultaneous defibrillators was 56.2 ± 9.51 while the remaining patients in Group B had a mean BMI of 35.9 ± 9.81 ( P < 0.0001).…”
Section: Discussionmentioning
confidence: 49%
“…The sample size was determined using assumptions based on prior published studies. 14,18,28 Using an expected efficacy of 75% for single DCCV and 90% for dual DCCV, we calculated that enrolling 200 patients and randomizing 1:1 would result in 80% power at a 2-sided α = .05. The statistical analysis was performed using the principle of intention to treat.…”
Section: Methodsmentioning
confidence: 99%
“…Dual DCCV, in contrast to the conventional approach using a single set of pads (single DCCV), uses 2 sets of defibrillator pads to administer simultaneous shocks, resulting in higher cumulative energy and current density delivered to the atrial myocardium . Dual DCCV has historically been used as salvage therapy for patients with AF refractory to maximum energy single DCCV, with previous case reports and retrospective analyses demonstrating this strategy to be potentially more effective and safe . In response to the notably elevated rate of cardioversion failure among patients with obesity, this study sought to evaluate the comparative effectiveness of dual DCCV vs single DCCV as an initial therapeutic approach for managing AF in this specific patient population.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations