2020
DOI: 10.1016/j.talanta.2019.120450
|View full text |Cite
|
Sign up to set email alerts
|

Effective quantification of 11 tyrosine kinase inhibitors and caffeine in human plasma by validated LC-MS/MS method with potent phospholipids clean-up procedure. Application to therapeutic drug monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
41
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 49 publications
(42 citation statements)
references
References 37 publications
1
41
0
Order By: Relevance
“…Huynh et al [15] developed an HPLC-MS/MS method for the simultaneous quantification of 14 tyrosine kinase inhibitors of clinical relevance; however, this method was not applied to measuring PNT in leukemia patient. Extraction procedures varied from liquid-liquid extraction [16, 17] to SPE purification [18] or protein precipitation [15]. Here, we described a cheap HPLC-MS/MS method that only required one-step deproteinization.…”
Section: Discussionmentioning
confidence: 99%
“…Huynh et al [15] developed an HPLC-MS/MS method for the simultaneous quantification of 14 tyrosine kinase inhibitors of clinical relevance; however, this method was not applied to measuring PNT in leukemia patient. Extraction procedures varied from liquid-liquid extraction [16, 17] to SPE purification [18] or protein precipitation [15]. Here, we described a cheap HPLC-MS/MS method that only required one-step deproteinization.…”
Section: Discussionmentioning
confidence: 99%
“…Koller et al developed an LC-MS/MS method for the simultaneous monitoring of 11 tyrosine kinase inhibitors (imatinib, dasatinib, nilotinib, bosutinib, ponatinib, ruxolitinib, brutinib, filgotinib, tofacitinib, baricitinib, and peficitinib) in human plasma [ 39 ]. Endogenous blood plasma phospholipids, proteins, salts, other blood plasma components, and exogenous substances can influence the chromatographic separation of analytes and the ionization process.…”
Section: Anticancer Drugsmentioning
confidence: 99%
“…Recently, several analytical methods for TKIs, based on LC/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/ MS), have been developed for clinical application of routine TDM and pharmacokinetics/pharmacodynamics studies (Koller et al, 2020;Merienne et al, 2018;Mukai et al, 2020). A standard curve and quality control samples are required for daily validation of the system before analysis.…”
Section: Introductionmentioning
confidence: 99%