1989
DOI: 10.1016/s0378-4347(00)82886-8
|View full text |Cite
|
Sign up to set email alerts
|

Effective monitoring of residues of nortestosterone and its major metabolite in bovine urine and bile

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
32
0

Year Published

1998
1998
2019
2019

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 62 publications
(33 citation statements)
references
References 5 publications
1
32
0
Order By: Relevance
“…The synthetic anabolic steroid 19-nortestosterone (19NT) and its esters have been reported as widely used for growth promotion purposes in cattle. 2 The target residues generally investigated for surveillance of abuse are 17b-19NT and (primarily) the 17a-epimer in urine and bile; these analytes would be determined following incubation with hydrolytic enzymes to liberate free steroid from conjugates. [2][3][4] The evidence that the 17a-epimer is the primary metabolite in bovine is scant, since the only in vivo 19NT radiotracer study reported for cattle 5 did not involve the investigation of biotransformation products.…”
Section: Introductionmentioning
confidence: 99%
“…The synthetic anabolic steroid 19-nortestosterone (19NT) and its esters have been reported as widely used for growth promotion purposes in cattle. 2 The target residues generally investigated for surveillance of abuse are 17b-19NT and (primarily) the 17a-epimer in urine and bile; these analytes would be determined following incubation with hydrolytic enzymes to liberate free steroid from conjugates. [2][3][4] The evidence that the 17a-epimer is the primary metabolite in bovine is scant, since the only in vivo 19NT radiotracer study reported for cattle 5 did not involve the investigation of biotransformation products.…”
Section: Introductionmentioning
confidence: 99%
“…GC-MS is widely used for the quantification of a-NT in bovine bile (16,27) and the sensitivity of the assay is improved with IAC pretreatment (27). IAC purification also reduces the probability of spurious false positive results (8) immunoreactive (EIA) concentrations for a-NT in male cattle and relate these to actual (GC-MS) concentrations.…”
Section: Assay Performancementioning
confidence: 99%
“…In the EU, unofficial screening and confirmatory action limits of 2 ng/ml have been set for bovine urine (23). In Northern Ireland, bile is used for screening because concentrations of a-NT are higher than in urine (27); the 2 ng/ml limit is applied. Any sample containing more than 2 ng/ml of a-NT is analysed by GC-MS.…”
mentioning
confidence: 99%
“…Conventional chromatographic methods, such as gas chromatography (GC) or liquid chromatography (HPLC) coupled to mass spectrometry (MS) and tandem mass spectrometry (MS-MS), are then used as confirmatory methods because of the high specificity of the information from the molecular structure of the analyte (9)(10)(11).…”
Section: Introductionmentioning
confidence: 99%