2013
DOI: 10.1155/2013/702427
|View full text |Cite
|
Sign up to set email alerts
|

Effective Assessment of Diabetes Control Using Personal Glucometers (CONTOURLINK, Bayer, Germany; CALLA, Wellion, Austria; LINUS, Agamatrix, USA)

Abstract: Aim of this trial was to assess (1) the accuracy and precision of electrochemistry-based glucometers CONTOURLINK, CALLA, and LINUS and (2) the diabetes control using Ambulatory Glycaemic Profiles (AGP) as markers of therapeutic effectiveness. Glucometers and COBAS INTEGRA 400 Plus analyzer were used by one laboratory professional to estimate P-glucose (PG) in 112 out-patients. There were 112 sets of 12 PG estimations analyzed. In each set, means of 3 capillary PG estimations on 3 respective glucometers and on … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 26 publications
0
8
0
Order By: Relevance
“…Glucose concentration in BAL samples was measured using the COBAS Integra 400 (Roche Diagnostics GmbH, Mannheim), with the Glucose HK Gen.3 assay (Roche Diagnosis) 42 . Blood glucose concentration was measured by a glucometer (Precision QID, MediSense, Sao Paulo, SP, Brazil).…”
Section: Methodsmentioning
confidence: 99%
“…Glucose concentration in BAL samples was measured using the COBAS Integra 400 (Roche Diagnostics GmbH, Mannheim), with the Glucose HK Gen.3 assay (Roche Diagnosis) 42 . Blood glucose concentration was measured by a glucometer (Precision QID, MediSense, Sao Paulo, SP, Brazil).…”
Section: Methodsmentioning
confidence: 99%
“…Strong correlations between PG values estimated on COBAS INTEGRA analyser vs. individual glucometers (CONTOURLINK, CALLA, LINUS) were shown (Figure 7). Correlations (Spearman) between PG estimations on INTEGRA vs. CALLA [19] Deviations from INTEGRA were within the range ± 15%. (Figure 8) PG variability was measured by SD: SD INTEGRA = 0.061 mmol/l, SD CONTOURLINK = 0.256 mmol/l, SD CALLA = 0.290 mmol/l, SD LINUS = 0.286 mmol/l.…”
Section: Trials For Testing Accuracy and Precision Of Glucometer-strimentioning
confidence: 84%
“…The purpose of our last experimental and clinical trial (2010-2013) [19] was (1) to assess the electrochemistry-based glucometers CONTOURLINK (Bayer, Germany) using glucose dehydrogenase strips, CALLA, (Wellion, Austria) and LINUS (Agamatrix, USA) both using glucose oxidase strips; (2) to evaluate diabetes control using Ambulatory Glycaemic Profiles (AGP) and comparing the results with those of the COBAS INTEGRA 400 Plus analyser. There were 112 sets (each from one person) analysed.…”
Section: Trials For Testing Accuracy and Precision Of Glucometer-strimentioning
confidence: 99%
See 1 more Smart Citation
“…From1974, following the introduction of glucometers into daily routine, self-monitoring of plasma/ blood glucose (SMPG/SMBG) became the predominant mode of glucose monitoring 6 . From the year 2000, the use of continuous glucose monitoring systems (CGMS) has shown remarkable benefits for both people with type 1 and type 2 diabetes [7][8][9][10][11][12] .…”
Section: Introductionmentioning
confidence: 99%