2008
DOI: 10.1109/tie.2008.918644
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Zero-Vector Placement in a Dual-Inverter Fed Open-End Winding Induction-Motor Drive With a Decoupled Space-Vector PWM Strategy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
64
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 167 publications
(64 citation statements)
references
References 23 publications
0
64
0
Order By: Relevance
“…T gb = T bs + T offset (11) T gc = T cs + T offset (12) where T ga , T gb and T gc are the gating signals during which the top switches in a leg are turned on.…”
Section: Svpwm Using a Reduced Computation Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…T gb = T bs + T offset (11) T gc = T cs + T offset (12) where T ga , T gb and T gc are the gating signals during which the top switches in a leg are turned on.…”
Section: Svpwm Using a Reduced Computation Methodsmentioning
confidence: 99%
“…Sector identification can be done by coordinate transformation as introduced in [8][9][10] or by repeated comparison of the three-phase reference voltages as introduced in [6][7][8][9][10][11]. The lookup tables can be used for determining the switching vectors in best switching sequence as introduced in [12]. Calculating the duration of the switching vectors can be simplified by mapping the sector of the multilevel inverter to a corresponding sector of the two-level inverter as introduced in [13,14].…”
Section: Introductionmentioning
confidence: 99%
“…Six of these switching states are active states, but the switching states (111) and (000) are zero/passive [2,[6][7][8][9].…”
Section: Description Of Sv-pwm Control On 2-level Vsimentioning
confidence: 99%
“…This paper is focused on the development of a general technique of SV-PWM in 2-level 3-phase VSIs [2], aiming at their utilization for driving variable speed 3-phase induction motors of medium power. One of the major issues faced in power electronic design is the reduction of harmonic content in inverter circuits [6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…The first one used the unified voltage modulation strategy [18] and the 180° decoupled PWM strategy [19] to adjust the duration of the small vectors so that the mean zero-sequence voltage is zero during each switching cycle. Then the zero-sequence voltage is dynamically eliminated [20]. The other way is the biasing inverter PWM strategy [6] where the mean value of summation of threephase voltage is zero.…”
Section: Introductionmentioning
confidence: 99%