2020
DOI: 10.1016/j.ijthermalsci.2020.106261
|View full text |Cite
|
Sign up to set email alerts
|

Effect of wing-pitch ratio of double-sided delta-wing tape insert on the improvement of convective heat transfer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
10
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(15 citation statements)
references
References 22 publications
3
10
0
Order By: Relevance
“…e best and worst values of each criterion are calculated using equation (32) and are depicted in Table 13, followed by the construction of utility measure relation, regret measure relation, and VIKOR index using equations ( 33)- (35) shown in Table 14. e ranking of the options is prioritized according to the VIKOR index value, as shown in Table 14 and Figure 17.…”
Section: Ranking the Alternativesmentioning
confidence: 99%
See 1 more Smart Citation
“…e best and worst values of each criterion are calculated using equation (32) and are depicted in Table 13, followed by the construction of utility measure relation, regret measure relation, and VIKOR index using equations ( 33)- (35) shown in Table 14. e ranking of the options is prioritized according to the VIKOR index value, as shown in Table 14 and Figure 17.…”
Section: Ranking the Alternativesmentioning
confidence: 99%
“…Hence, the optimization of grooved tube heat exchanger is essential for obtaining high performance with energy saving and pumping cost reduction [33,34]. Blade vortex generator inserts, multiple helical tape inserts, and diverging perforated cones are special types of inserts that are used as turbulators to reduce the flow blockage in downstream conditions and improve the Reynolds number [35]. Wijayanta et al [36] proposed that delta wing tape turbulators raise the heat transfer performance by 177% and their design configurations are optimized using the ANN method [37].…”
Section: Introductionmentioning
confidence: 99%
“…Skullong [15] Pourhedayat et al, [16] Khoshvaght-Aliabadi et al, [19] Boonloi and Jedsadaratanachai [18] Gururatana et al, [17] Wijayanta et al, [20] Skullong et al, [1] Fig.…”
Section: Promvonge Andmentioning
confidence: 99%
“…Figure 6 shows the copper tube with a sparsely placed twisted tape combined with multiple transverse twisted baffles. Wijayantaa et al, [15] illustrated the limited number of studies of heat transfer enhancement regarding the wingpitch ratio. To experiment in this field, they improved single-phase convective heat transfer with water as working fluid under a condition of 5,300 to 14,500 Reynolds number.…”
Section: A B Cmentioning
confidence: 99%
“…To experiment in this field, they improved single-phase convective heat transfer with water as working fluid under a condition of 5,300 to 14,500 Reynolds number. It is revealed from the study that the delta wing tape inserts with a wing-pitch ratio of 1.18 produces the greatest thermal performance factor of 1.15 and offers the highest average Nusselt number of 177% compared to a plain tube [15]. Figure 7(a) shows the geometry and Figure 7(b) illustrates the photograph of the delta wing tape inserts.…”
Section: A B Cmentioning
confidence: 99%