2017
DOI: 10.1063/1.4968277
|View full text |Cite
|
Sign up to set email alerts
|

Effect of water temperature and air stream velocity on performance of direct evaporative air cooler for thermal comfort

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
4
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 8 publications
0
4
0
1
Order By: Relevance
“…The first was the cooling pad which covers variables such as material specifications, area, and thickness (Elmsaad and Omran 2015;Warke and Deshmukh 2017;Abohorlu Doğramacı et al 2019;Susila, Wijaksana, and Suarnadwipa 2019;Abaranji, Panchabikesan, and Ramalingam 2020;Ahmad, Malek, and Rahman 2017;Esparza L. et al 2018). The second airstream velocity, air temperature, and water volume in the system (Aziz et al 2017;Warke and Deshmukh 2017;Susila, Wijaksana, and Suarnadwipa 2019), and the last integration with other techniques to improve the performance of DEC (Darmawan, Wijaksana, and Suarnadwipa 2021;Xu et al 2016). These studies focused mainly on developing technical aspects of the cooler system, and none of them was applied explicitly to housing units.…”
Section: Introductionmentioning
confidence: 99%
“…The first was the cooling pad which covers variables such as material specifications, area, and thickness (Elmsaad and Omran 2015;Warke and Deshmukh 2017;Abohorlu Doğramacı et al 2019;Susila, Wijaksana, and Suarnadwipa 2019;Abaranji, Panchabikesan, and Ramalingam 2020;Ahmad, Malek, and Rahman 2017;Esparza L. et al 2018). The second airstream velocity, air temperature, and water volume in the system (Aziz et al 2017;Warke and Deshmukh 2017;Susila, Wijaksana, and Suarnadwipa 2019), and the last integration with other techniques to improve the performance of DEC (Darmawan, Wijaksana, and Suarnadwipa 2021;Xu et al 2016). These studies focused mainly on developing technical aspects of the cooler system, and none of them was applied explicitly to housing units.…”
Section: Introductionmentioning
confidence: 99%
“…O comporamento distinto da umidade relativa nos dois aviários, apesar de apresentarem comportamento similar de temperatura, esteve diretamente relacionado a temperatura da água utilizada nos resfriadores evaporativos. Aziz, Mainil, Mainil & Listiono (2017) avaliando a influência da temperatura da água e da vazão de ar em um resfriador evaporadorativo direto, verificaram que a umidade relativa tendeu a aumentar com o aumento da temperatura e, que a eficiência de resfriamento aumentou com a redução da temperatura da água.…”
Section: Fonte: Autores (2020)unclassified
“…Also, the Perpendicular direction of airflow results in the highest cooling capacity compared with other directions. Aziz et al [16] experimentally investigated the effect of water temperature from 100C to 500C with the increment of 100 and airstream velocity for 2.9 m/s, 3.9 m/s, and 4.5 m/s on the performance of direct evaporative air cooler for thermal comfort. Results show that relative humidity increases with water temperature but is unaffected by the airstream velocity.…”
Section: Introductionmentioning
confidence: 99%