2019
DOI: 10.1016/j.energy.2019.115962
|View full text |Cite
|
Sign up to set email alerts
|

Effect of velocity non-uniformity of supply air on the mixing characteristics of push-pull ventilation systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(10 citation statements)
references
References 30 publications
0
10
0
Order By: Relevance
“…Before reviewing the results of the analysis, it is necessary to ensure the accuracy of the simulation performed. One way to validate the results of numerical solution is to check the airflow velocity between the jet and the hood and compare it with the results of Wang et al [5]…”
Section: Mesh Independencymentioning
confidence: 99%
See 1 more Smart Citation
“…Before reviewing the results of the analysis, it is necessary to ensure the accuracy of the simulation performed. One way to validate the results of numerical solution is to check the airflow velocity between the jet and the hood and compare it with the results of Wang et al [5]…”
Section: Mesh Independencymentioning
confidence: 99%
“…Numerous studies have been performed on blowing-suction ventilation systems numerically and in the past. In a study, Wang et al [5] investigated the mixing characteristics of different blowing airflow profiles and changes in the direction of blowing flow in a twodimensional and laboratory numerical study. Using equation of species transfer and equations of energy, momentum, continuity and mass survival, they simulated the mixing of ambient air with the exhaust air of the jet and obtained the amount of mixing of ambient air with the jet air under the above conditions.…”
Section: Introductionmentioning
confidence: 99%
“…Compared with local exhaust ventilation, push-pull ventilation has better contaminants control due to increased air supply [ 3 , 4 ]. Parallel push-pull ventilation uses the low turbulence intensity, uniform and wide air flow with directionality to push the contaminants into the exhaust outlet [ 5 , 6 ], which has been widely used in workplace contaminants control such as painting [ 7 , 8 ], printing [ 9 ] and cleaning using organic solvent [ 10 , 11 ], welding [ 12 ] and pathology laboratories [ 13 ].…”
Section: Introductionmentioning
confidence: 99%
“…Air-mixing is another standard method to mix fluid, gas, or powder through the blower and pump, 22 , 23 which has been widely used in the fuel-/air-mixing apparatus, 24 , 25 ventilation systems, 26 and aerodynamic simulation. 27 Many scholars 28 , 29 have studied the mixing characteristics of jets under different exit shapes. For the polymer flooding in EOR, after the premixing by Venturi jetting or the air-mixing, the water–polymer powder mixture is transferred to the stirring tank for further mixing and curing.…”
Section: Introductionmentioning
confidence: 99%
“…The Venturi jetting is becoming the standard for a proportional to complete a mixture of two liquids in the process industry. , Numerical and experimental studies on mixing behavior of Venturi jet, such as geometry optimization, device design, , and mixing hydrodynamics, have received considerable attention in recent years. Air-mixing is another standard method to mix fluid, gas, or powder through the blower and pump, , which has been widely used in the fuel-/air-mixing apparatus, , ventilation systems, and aerodynamic simulation . Many scholars , have studied the mixing characteristics of jets under different exit shapes.…”
Section: Introductionmentioning
confidence: 99%