2018
DOI: 10.1016/j.postharvbio.2017.11.007
|View full text |Cite
|
Sign up to set email alerts
|

Effect of UV-C on the physiology and biochemical profile of fresh Piper nigrum berries

Abstract: HighlightsUV-C caused significant changes in colour (from green to brown).A low UV-C dose significantly increased piperine and essential oil content.A newly developed simultaneous extraction method is discussed.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
17
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(18 citation statements)
references
References 17 publications
(18 reference statements)
0
17
0
1
Order By: Relevance
“…After 1-MCP treatment, tubers were ventilated for 24 h and then transferred to Cranfield University (Bedfordshire, UK) within 2 h whereupon they were promptly sorted across treatments and stored in gas-tight boxes (100 L, water-sealed) inside variable temperature rooms. The boxes were continuously flushed (5 L min −1 ) with air (Control, -C) or ethylene (-E), 10 μL L −1 , as previously described ( Amoah et al, 2017 ; Collings et al, 2018 ).…”
Section: Methodsmentioning
confidence: 99%
“…After 1-MCP treatment, tubers were ventilated for 24 h and then transferred to Cranfield University (Bedfordshire, UK) within 2 h whereupon they were promptly sorted across treatments and stored in gas-tight boxes (100 L, water-sealed) inside variable temperature rooms. The boxes were continuously flushed (5 L min −1 ) with air (Control, -C) or ethylene (-E), 10 μL L −1 , as previously described ( Amoah et al, 2017 ; Collings et al, 2018 ).…”
Section: Methodsmentioning
confidence: 99%
“…Each replicate was then placed in a 3 L sealed gas jar with gas inlet for air supply and outlet for respiration rate measurement as CO 2 production. The measured CO 2 produced (in mL h −1 ) was adjusted to get the final respiration rate values as CO 2 produced in milligrams per kilogram of bulb weight per hour (mg kg −1 h −1 ) as previously described by Collings et al (2018).…”
Section: Methodsmentioning
confidence: 99%
“…Ethylene production was analysed using an ETD-300 Ethylene Detector with a CAT-1 catalyser and VC-1 valve control box (Sensor Sense, Netherlands). Samples (n = 9 and 18 shoots for Clone 2 and Yabukita, respectively) were placed into cuvettes (250 mL) which had a continuous flow (4 L h −1 ) of hydrocarbon free air flushing through (Collings, Gavidia, Cools, Redfern, & Terry, 2018). A stable baseline measurement, obtained using an empty cuvette, was recorded at the beginning and end of each run to allow values to be adjusted by removing the baseline.…”
Section: Methodsmentioning
confidence: 99%
“…Objective colour (lightness (L*), chroma (C*) and hue angle (h°) were measured using a Minolta CR-400 colourimeter with an 8 mm light aperture and DP-400 data processor (Minolta Co. Ltd., Japan) (Collings et al, 2018). The mean was calculated based on three readings measured from the largest leaf.…”
Section: Methodsmentioning
confidence: 99%