1992
DOI: 10.1080/1047322x.1992.10390201
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Ultraviolet Germicidal Lamps on Airborne Microorganisms in an Outpatient Waiting Room

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
42
0

Year Published

1995
1995
2017
2017

Publication Types

Select...
3
3
2

Relationship

0
8

Authors

Journals

citations
Cited by 64 publications
(42 citation statements)
references
References 23 publications
0
42
0
Order By: Relevance
“…The lower limit (30 colonies) is to obtain suf cient statistical power for comparison purposes. The limit (300 colonies) is the maximum range in which one could easily count and differentiate colonies (Jensen et al 1994;Chang et al 1994). There was only 1 sampling port, and samples were taken in sequence rst without and then with UVGI irradiation.…”
Section: Aerosol Test System (As Shown Inmentioning
confidence: 99%
See 1 more Smart Citation
“…The lower limit (30 colonies) is to obtain suf cient statistical power for comparison purposes. The limit (300 colonies) is the maximum range in which one could easily count and differentiate colonies (Jensen et al 1994;Chang et al 1994). There was only 1 sampling port, and samples were taken in sequence rst without and then with UVGI irradiation.…”
Section: Aerosol Test System (As Shown Inmentioning
confidence: 99%
“…Moreover, a twelve-fold bacterial colony reduction was reported in 475 an operating room with a high level of UVGI at 290 ¹W/cm 2 (Lidwell 1994). In a well-ventilated hospital waiting room equipped with wall-mounted lamps, it was demonstrated that there was a 14-19% reduction in culturable bacterial concentrations (Macher et al 1992(Macher et al , 1994. Therefore UVGI should be a very promising technique for indoor microorganism control.…”
Section: Introductionmentioning
confidence: 99%
“…UVGI has advantages and disadvantages relative to other engineering controls (Macher 1993;CDC 1994;NIOSH 1997) and has returned to the arsenal of TB control measures because of its low cost, ease of application, and potential ef cacy, despite past failure in some settings to reduce the concentration of airborne microorganisms substantially (Goldner et al 1980;Macher et al 1992Macher et al , 1994 or to prevent airborne disease transmission (Nardell 1995).…”
Section: Introductionmentioning
confidence: 99%
“…Lidwell (1994) reported a twelve-fold reduction in viable, ambient airborne bacteria in an operating room with high levels of UVGI (290 l W cm ¡ 2 ). Macher et al (1992Macher et al ( , 1994) saw a 14-19% reduction in the concentration of viable, ambient bacteria in a well-ventilated hospital waiting room equipped with wall-mounted lamps.…”
Section: Introductionmentioning
confidence: 99%
“…Modern living standards and building systems have increased the numbers of settings that have relatively high concentrations of bioaerosols (high-exposure environments), which have been implicated to increase cases of respiratory and pulmonary diseases. [1][2][3] These high-exposure environments include correctional facilities, 4 healthcare facilities, 5,6 shelters for the homeless, wastewater treatment plants, 7 and public transit systems. 8 More recently, buildings housing hospital therapy pools, "hot tubs," and other warm-water leisure and therapy pools have been implicated to support and aerosolize microorganisms that include opportunistic pathogens from the genera Legionella and Mycobacterium, 9 -11 causing diseases such as "lifeguard lung."…”
Section: Introductionmentioning
confidence: 99%