BackgroundLaparoscopic appendectomy (LA) has become one of the most common surgical procedures to date. To improve and standardize this technique further, cost-effective and reliable animal models are needed.MethodsIn a pilot study, 30 Wistar rats underwent laparoscopic caecum resection (as rats do not have an appendix vermiformis), to optimize the instrumental and surgical parameters. A subsequent test study was performed in another 30 rats to compare three different techniques for caecum resection and bowel closure.ResultsBipolar coagulation led to an insufficiency of caecal stump closure in all operated rats (Group 1, n = 10). Endoloop ligation followed by bipolar coagulation and resection (Group 2, n = 10) or resection with a LigaSure™ device (Group 3, n = 10) resulted in sufficient caecal stump closure.ConclusionsWe developed a LA model enabling us to compare three different caecum resection techniques in rats. In conclusion, only endoloop closure followed by bipolar coagulation proved to be a secure and cost-effective surgical approach.