2014
DOI: 10.1016/j.aej.2014.01.009
|View full text |Cite
|
Sign up to set email alerts
|

Effect of tension lap splice on the behavior of high strength self-compacted concrete beams

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0
1

Year Published

2014
2014
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 2 publications
0
10
0
1
Order By: Relevance
“…However, the experiment did not measure the possibility of the slippage of the reinforcement in the spliced zone. What can simply be pointed out from the current experimental results is that there is a minimum splice length of tensile reinforcement to meet a comparable stiffness with the corresponding beam with non-spliced reinforcement [27].…”
Section: Stiffness Index (Si)mentioning
confidence: 72%
See 1 more Smart Citation
“…However, the experiment did not measure the possibility of the slippage of the reinforcement in the spliced zone. What can simply be pointed out from the current experimental results is that there is a minimum splice length of tensile reinforcement to meet a comparable stiffness with the corresponding beam with non-spliced reinforcement [27].…”
Section: Stiffness Index (Si)mentioning
confidence: 72%
“…The findings are consistent with that found in the literature where beams with sufficient tensile splice length show a flexural failure mode. On the contrary, beams with short splice length demonstrate a splitting failure mode [27]. For the case of plain reinforcement, insufficent splice length more likely to cause a slippage (pull out) failure mode rather than splitting failure [24].…”
Section: Crack Patternmentioning
confidence: 99%
“…The experimental results of the current research in addition to the results of previous work were used to validate the proposed model. Eighty-three beams splice specimens of Darwin et al, 14 70 beams splice specimens of Azizinamimi et al, 28 and three direct tension splices of the current research were used. Nineteen beams splice specimens were eliminated from verification because they failed away of splice due to other reasons.…”
Section: Validation Of the Proposed Modelmentioning
confidence: 99%
“…Not only the bond strength is affected by increasing the concrete cover and bar spacing, but also mode of failure can be altered. 4,5,14,15 Pullout failure is recorded for cases with large concrete cover and bar spacing; however, splitting tensile failure takes place for smaller concrete cover and bar spacing. In addition, pullout failures can take place with slightly observed splitting cracks in case of spliced bars with a proper confinement (ACI 408R-03).…”
Section: Introductionmentioning
confidence: 99%
“…El Azab vd. [9] ise yüksek dayanımlı kendiliğinden yerleşen beton kullanılan çekme bölgesinde bindirme ekine sahip kirişlerin davranışına donatı çapı, oranı, bindirme boyu uzunluğu ve betonun kiriş üzerindeki döküm konumunun etkisini incelemiştir.…”