1995
DOI: 10.1016/0584-8539(94)00163-6
|View full text |Cite
|
Sign up to set email alerts
|

Effect of solvent and pH on the spectral characteristics of meso-tetrakis(p-hydroxyphenyl) porphyrin in dimethylformamide and dimethylformamide + water mixed solvents

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0
2

Year Published

2005
2005
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(15 citation statements)
references
References 14 publications
0
13
0
2
Order By: Relevance
“…The overcrowding thus created in the centre is responsible for the distortion of the ring structure of the planar porphyrin. This increased charge density in the core region transforms the spectrum to acid type expected for D 4h symmetry, associated to the enhancement intensity for band QI which is forbidden otherwise [9].…”
Section: Resultsmentioning
confidence: 97%
“…The overcrowding thus created in the centre is responsible for the distortion of the ring structure of the planar porphyrin. This increased charge density in the core region transforms the spectrum to acid type expected for D 4h symmetry, associated to the enhancement intensity for band QI which is forbidden otherwise [9].…”
Section: Resultsmentioning
confidence: 97%
“…Generally,pHplays an important role in maintaining the stability,n ormal morphology,a nd function of cells and organisms.D ue to the spectral characteristics that change upon protonation/deprotonation of the pyrrole ring in porphyrins with ac hange in pH, [101] porphyrin-based MOFs could be used to construct pH sensors,showing great potential in pH monitoring,d isease diagnosis,a nd even evaluating therapeutic efficacy.In2013, Zhou et al reported for the first time Zr-based porphyrinic MOF PCN-225 and metalloporphyrinic MOF PCN-225(Zn) for pH sensing. [35b] Ther esults demonstrated that the fluorescence intensity of PCN-225 has astrong correlation with the pH of the solution in the range of pH 0-10.2.…”
Section: 4 Ph Sensingmentioning
confidence: 99%
“…Generally, pH plays an important role in maintaining the stability, normal morphology, and function of cells and organisms. Due to the spectral characteristics that change upon protonation/deprotonation of the pyrrole ring in porphyrins with a change in pH, [101] porphyrin‐based MOFs could be used to construct pH sensors, showing great potential in pH monitoring, disease diagnosis, and even evaluating therapeutic efficacy. In 2013, Zhou et al.…”
Section: Biomedical Applications Of Porphyrin‐based Mofsmentioning
confidence: 99%
“…Im Allgemeinen spielt der pH-Wert eine wichtige Rolle bei der Aufrechterhaltung der Stabilität, der Morphologie und der Zellfunktionen des Organismus.D urch einen veränderten pH-Wert, also durch Protonierung oder Deprotonierung,k çnnen die spektroskopischen Eigenschaften der Pyrrole in den Porphyrinringen verändert werden. [101] Dementsprechend kçnnen PMOFs eingesetzt werden, um pH-Sensoren zu entwickeln, welche außer zur Messung des pH-Werts ebenfalls fürdie Erkrankungsdiagnose oder gar fürdie Bewertung der therapeutischen Wirksamkeit eingesetzt werden. 2013 publizierten Zhou et al zum ersten Mal ein Zrbasiertes PMOF,P CN-225, und das metalloporphyrinische MOF PCN-225(Zn) fürd ie pH-Wert Sensorik.…”
Section: 4 Ph-sensorikunclassified