2015
DOI: 10.3233/thc-150916
|View full text |Cite
|
Sign up to set email alerts
|

Effect of six degrees of freedom knee kinematics on ligament length and moment arm in an intact knee model

Abstract: Abstract. BACKGROUND:Biomechanics studies can help improve athletic performance. However, the biomechanics of knee joint ligament length changes and moment arms over six degrees of freedom (DOF) have yet to be established. OBJECTIVE: To construct a knee model to investigate the length and moment arm changes of the anterior cruciate ligament (ACL), posterior cruciate ligament (PCL), medial collateral ligament (MCL), and lateral collateral ligament (LCL). METHOD: Six DOF joint modeling and analysis were performe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
15
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(15 citation statements)
references
References 34 publications
0
15
0
Order By: Relevance
“…According to the quality assessment results presented in Table 2 , several articles had limited modelling technique descriptions [ 15 , 16 , 19 , 20 , 27 , 33 ] and validation methods [ 16 , 18 , 25 , 27 , 35 , 37 , 38 ]. In 12 of the selected studies [ 14 17 , 20 , 24 27 , 31 , 37 , 38 ], the sensitivity of the model outputs on ligament model parameters has not been assessed.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…According to the quality assessment results presented in Table 2 , several articles had limited modelling technique descriptions [ 15 , 16 , 19 , 20 , 27 , 33 ] and validation methods [ 16 , 18 , 25 , 27 , 35 , 37 , 38 ]. In 12 of the selected studies [ 14 17 , 20 , 24 27 , 31 , 37 , 38 ], the sensitivity of the model outputs on ligament model parameters has not been assessed.…”
Section: Resultsmentioning
confidence: 99%
“…A range of musculoskeletal modelling software packages has been used across the selected studies ( Fig 2A and Table 3 ). 14 studies [ 15 17 , 20 25 , 27 , 29 , 32 , 34 , 35 ] used OpenSim [ 39 ], four studies [ 18 , 36 38 ] used SIMM [ 40 ], two studies [ 26 , 28 ] used AnyBody Modelling System (AnyBody Technology, Aalborg, Denmark), one study [ 30 ] used ADAMS [ 41 ], one study [ 14 ] used SimWise-4D platform (Design Simulation Technologies, DST, Canton, MI, USA), one study [ 19 ] used KneeSIM (LifeModeler Inc., San Clemente, CA), one study [ 33 ] used Musculoskeletal Joint Modeler [ 42 ], and one study [ 31 ] used Working Model 3D (Working Model 3D, MSC, Software Corp., Santa Ana, CA, USA).…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations