2016 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) 2016
DOI: 10.1109/speedam.2016.7525968
|View full text |Cite
|
Sign up to set email alerts
|

Effect of sampling frequency and execution time on hysteresis current controlled three-phase three-wire HAPF converters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 36 publications
0
3
0
Order By: Relevance
“…11 shows the block diagram comprising every step of the process. First, a sampled HBCC is used to inject harmonic currents into the grid, which is digitally implemented by comparing the current error normalΔi with the hysteresis band δ [30], selected as 1% of the operational current, and then the switches S+ and S are turned on or off accordingly. Then, phase voltage va,inv is measured at the converter's output along with the current ia, and both signals go through a DFT algorithm to extract the desired harmonic components, Vh and Ih, as well as the respective phases, θVh and θIh.…”
Section: Proposed Methodologymentioning
confidence: 99%
“…11 shows the block diagram comprising every step of the process. First, a sampled HBCC is used to inject harmonic currents into the grid, which is digitally implemented by comparing the current error normalΔi with the hysteresis band δ [30], selected as 1% of the operational current, and then the switches S+ and S are turned on or off accordingly. Then, phase voltage va,inv is measured at the converter's output along with the current ia, and both signals go through a DFT algorithm to extract the desired harmonic components, Vh and Ih, as well as the respective phases, θVh and θIh.…”
Section: Proposed Methodologymentioning
confidence: 99%
“…In Fig. 1 c , filter current is shown to change linearly after each switching instant by taking into consideration of Assumption 2. Assumption 2 (linear LC filter response and fast control hardware assumption): Execution time, T e , sampling period, T s and hysteresis band, Δ I , are small enough such that LC filter response can be considered linear [38, 43]. Also, the tracking error is negligible as compared to the hysteresis band because T e and T s are assumed to be small.…”
Section: Formulation Of Hysteresis Switching Behaviour Of Hapf Convmentioning
confidence: 99%
“…Fortunately, the THD value of the proposed method is still below the allowed limits, 5%, in standards [49] throughout the measurement period. The performance of the proposed method can also be optimised with the use of more powerful processors by increasing the computational capabilities and the sampling frequency [43].…”
Section: Field Implementationmentioning
confidence: 99%