Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2015
DOI: 10.1016/j.elstat.2015.05.019
|View full text |Cite
|
Sign up to set email alerts
|

Effect of relative humidity on current–voltage characteristics of monopolar DC wire-to-plane system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(11 citation statements)
references
References 19 publications
0
8
0
Order By: Relevance
“…As the applied voltage increased from 1.5 to 5.5 kV for a 1 cm gap space, an increase in the onset current was measured. This relationship, discussed in previous studies, is due to the increase in the electric field at the surface of the anode which leads to an increase in the total positive space charge, more ionizing collisions, and a greater number of charged ions contributing to the onset current …”
Section: Discussionmentioning
confidence: 85%
“…As the applied voltage increased from 1.5 to 5.5 kV for a 1 cm gap space, an increase in the onset current was measured. This relationship, discussed in previous studies, is due to the increase in the electric field at the surface of the anode which leads to an increase in the total positive space charge, more ionizing collisions, and a greater number of charged ions contributing to the onset current …”
Section: Discussionmentioning
confidence: 85%
“…The humidity is controlled with a three ways circuit with taps. Air is hydrated (14) with the water vapour provided by heating a half full bottle of distilled water; ways (13) and (15) being closed. The drying of the air is made by the way (16) in using silicagel contained in a bottle, when the ways (14) and (13) are closed.…”
Section: Experimental Apparatus and Methodsmentioning
confidence: 99%
“…The drying of the air is made by the way (16) in using silicagel contained in a bottle, when the ways (14) and (13) are closed. The opening of way (13), the closing of ways (14) and (15) of the circuit allow to keep a constant humidity inside the box. Air is then filtered (16) before it is let again in the box.…”
Section: Experimental Apparatus and Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Aissou et al . [9], with the biased‐current probe to measure the current density and electric field, analysed the behaviour of DC monopolar corona discharge in the wire‐to‐plane configuration under variable humid air conditions. Deng et al .…”
Section: Introductionmentioning
confidence: 99%