Effect of radioactivity outside the field of view on image quality of dedicated breast positron emission tomography: preliminary phantom and clinical studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…Moreover, referring to the clinical images, the SiPM-based TOF-PET images seemed to have more noise enhanced near the chest wall, especially the 18 F-FDG abnormal accumulation at the left myocardium ( Figure 7 ). The image quality of ring-shaped dbPET images was reported to be degraded at the detector edge due to FDG accumulated in the myocardium and other body parts, although sensitivity correction was performed [ 21 ]. Thus, in SiPM-based TOF-PET with a larger detector surface diameter, radioactivity outside the FOV may have a greater impact.…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, referring to the clinical images, the SiPM-based TOF-PET images seemed to have more noise enhanced near the chest wall, especially the 18 F-FDG abnormal accumulation at the left myocardium ( Figure 7 ). The image quality of ring-shaped dbPET images was reported to be degraded at the detector edge due to FDG accumulated in the myocardium and other body parts, although sensitivity correction was performed [ 21 ]. Thus, in SiPM-based TOF-PET with a larger detector surface diameter, radioactivity outside the FOV may have a greater impact.…”
Section: Discussionmentioning
confidence: 99%
“…This increases noise in dbPET images compared with whole-body PET images. These noises are sometimes difficult to distinguish from small lesions and can lead to false-negative or false-positive findings, which affect quantitative PET values such as SUV [ 7 , 24 ]. Increasing the acquisition time and injecting a sufficient FDG dose, which lead to increased patient burden and decreased test efficiency, are necessary to reduce noise.…”
Section: Discussionmentioning
confidence: 99%
“…Recently, dedicated breast PET (dbPET) that specializes in breast imaging has been developed, and basic and clinical studies using dbPET are underway [ 7 , 8 , 9 ]. dbPET can acquire data with higher spatial resolution than whole-body PET, thereby demonstrating higher sensitivity for BC detection [ 10 ].…”
Section: Introductionmentioning
confidence: 99%