2022
DOI: 10.1016/j.prosdent.2020.08.034
|View full text |Cite
|
Sign up to set email alerts
|

Effect of pulp chamber depth on the accuracy of endocrown scans made with different intraoral scanners versus an industrial scanner: An in vitro study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
30
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(38 citation statements)
references
References 28 publications
2
30
0
Order By: Relevance
“…This coincided with an increase in deviation along the prepared root canal from the occlusal internal to apical measurement areas in the present study. The preparation depth of endocrowns ranged from 2 to 5 mm [37]. Gurpinar et al reported at 5 mm is within the range determined in this study for the measurement areas of the first and second root canal thirds.…”
Section: Digital Impression Taking With Ios (Part A)supporting
confidence: 86%
See 2 more Smart Citations
“…This coincided with an increase in deviation along the prepared root canal from the occlusal internal to apical measurement areas in the present study. The preparation depth of endocrowns ranged from 2 to 5 mm [37]. Gurpinar et al reported at 5 mm is within the range determined in this study for the measurement areas of the first and second root canal thirds.…”
Section: Digital Impression Taking With Ios (Part A)supporting
confidence: 86%
“…Gurpinar et al [37] investigated the influence of endocrown preparation depth on the accuracy of digital impressions and reported a higher deviation for more deeply prepared endocrowns. This coincided with an increase in deviation along the prepared root canal from the occlusal internal to apical measurement areas in the present study.…”
Section: Digital Impression Taking With Ios (Part A)mentioning
confidence: 99%
See 1 more Smart Citation
“…31 In another recent study on local accuracy for crown and inlay preparations on a tooth, Primescan showed the highest accuracy among the IOS systems tested, and its accuracy approximated that of conventional impressions obtained with a polyvinylsiloxane elastomer. 13 Grupinar et al 32 investigated endocrown impressions and reported that Primescan showed the highest accuracy from among CEREC Omnicam, TRIOS 3, iTero Element 2, Planmeca Emerald, and Virtuo Vivo, irrespective of the depth of the cavity. The findings of these previous studies are consistent with those of the present study.…”
Section: Discussionmentioning
confidence: 99%
“…Intraoral scanners (IOS) haven’t traditionally been used for these indications mainly since digitizing root canal preparations was thought to be too challenging for dental optical scanners. However, recent advances in IOSs technology seem to allow the use of optical impressions in root canal preparations [ 7 , 8 , 9 , 10 , 11 ]. In addition to the usual advantages offered by computer-aided design and manufacturing (CAD-CAM): patient comfort, immediate control of preparation quality, or dematerialization of the workflow [ 12 , 13 , 14 ].…”
Section: Introductionmentioning
confidence: 99%