1973
DOI: 10.3181/00379727-143-37433
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Protein and Electrolyte on the Spectral Stabilization of Concentrated Solutions of Indocyanine Green

Abstract: In the measurement of flow by dye-dilution techniques, the optical density of the dyeblood mixture must stabilize in the interval between dilution and detection if an accurate measurement of flow is to be obtained. For many years indocyanine green (ICG), the most widely used dye in hemodynamic studies, was thought to sbabilize within 1.5 to 2 sec after dilution (1). However, a recent study ( 2 ) failed to reproduce these results. Another study ( 3 ) concluded that slow optical stabilization of ICG results in m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

1976
1976
2014
2014

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 1 publication
0
9
0
Order By: Relevance
“…ICG (Fig. 1) is purchased as a powder (Cardio-green; Hynson, Westcott & Dunning Products, Becton Dickinson Microbiology Systems, Cockeysville, USA) which is soluble in highly distilled water (Tripp et al 1973). The purification process leaves small amounts of NaI in the powder (Lutty 1978).…”
Section: Some Chemical Propertiesmentioning
confidence: 99%
See 2 more Smart Citations
“…ICG (Fig. 1) is purchased as a powder (Cardio-green; Hynson, Westcott & Dunning Products, Becton Dickinson Microbiology Systems, Cockeysville, USA) which is soluble in highly distilled water (Tripp et al 1973). The purification process leaves small amounts of NaI in the powder (Lutty 1978).…”
Section: Some Chemical Propertiesmentioning
confidence: 99%
“…It is highly hydrophobic and lipophilic, even compared to other cholephilic anions (Tazuma et al 1988), and this may be the reason why ICG does not pass dialysis membranes (Baker 1966;Gentile et al 1985). ICG is green with an absorption maximum of 780 nM in distilled water and methanol, 800 nm in an albumin containing solution, and 805 nm in plasma (Sutterer et al 1966;Gathje et al 1970;Tripp et al 1973;Valerie 1973;Gentile et al 1985). It is difficult to obtain a stable and simple solution of ICG in protein free buffer (Baker 1966;Sutterer et al 1966;Gathje et al 1970;Simmons & Shephard 1971;Valerie 1973;Bjornsson et al 1982;Rappaport & Thiessen 1982;Heintz et al 1986;Green 1992).…”
Section: Some Chemical Propertiesmentioning
confidence: 99%
See 1 more Smart Citation
“…This possibility is supported by the observation that species differences exist in the major indocyanine green binding protein fractions (Baker, 1966). One factor which might need to be considered when comparing different studies is that the physico-chemical properties of the dye and the rate of protein binding can be influenced by the solute composition of the indocyanine green dye solution infused (Baker, 1966;Tripp et al, 1973;Landsman et al, 1976).…”
Section: Discussionmentioning
confidence: 99%
“…The use of Sparling's (1961) method for calibration and patient's renal curves of approximately the same height strongly minimizes errors due to variations in the extinction of the dye. Distortions from Beer's law due to temperature differences, inappropriate solvent (Saunders et al, 1970;Simmons & Shephard, 1971;Tripp, Cohen, Gerash & Fox, 1973) or the presence of labelled erythrocytes in the IG solution, should affect the calibration curves to a comparable extent.…”
Section: Renal Blood Flowmentioning
confidence: 99%