2013
DOI: 10.1007/s12200-013-0313-2
|View full text |Cite|
|
Sign up to set email alerts
|

Effect of prism material on design of surface plasmon resonance sensor by admittance loci method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
13
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 42 publications
(16 citation statements)
references
References 12 publications
0
13
0
Order By: Relevance
“…Although the basic knowledge is easy to understand, such devices are relatively scarce because of the cost of the instrument as well as the maintenance process (Tang, Zeng & Liang, 2010;Lavine, Westover, Oxenford, Mirjankar & Kaval, 2007). Furthermore, from the theoretical point of view, several structural parameters could affect the performance of the device, like the effect of wavelength, the prism, and the film materials (Brahmachari & Ray, 2013;Fotana, 2006). To overcome this issue, a theoretical approach is considered as an appropriate strategy.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Although the basic knowledge is easy to understand, such devices are relatively scarce because of the cost of the instrument as well as the maintenance process (Tang, Zeng & Liang, 2010;Lavine, Westover, Oxenford, Mirjankar & Kaval, 2007). Furthermore, from the theoretical point of view, several structural parameters could affect the performance of the device, like the effect of wavelength, the prism, and the film materials (Brahmachari & Ray, 2013;Fotana, 2006). To overcome this issue, a theoretical approach is considered as an appropriate strategy.…”
Section: Introductionmentioning
confidence: 99%
“…In doing so, numerous papers have proposed theoretical modeling of SPR biosensor based on the Kretschmann configuration (Widayanti & Abraha, 2016;Verma, Gupta, RajanJh, 2011;Maurya, Prajapati & Tripathi, 2018;Bhavsar & Prabhu, 2019;Dai et al, 2019;Zhao et al, 2018). However, most of the works (Brahmachari & Ray, 2013;Sadowski, Korhonen & Peltonen, 1995;Sarid & Challener, 2010) done in the formulation and analysis of SPR was employed 84 specialized software. This report describes an easy method to utilize the free spreadsheets, Google Sheets, to simulate the SPR in the Kretschmann configuration (https://www.google.com/sheets).…”
Section: Introductionmentioning
confidence: 99%
“…Investigation on surface plasmon sensor comprising of high refractive index transparent ceramic prism material for improved sensitivity has been reported [7]. A work on prism material dependency of a plasmonic structure using admittance loci method has been reported earlier [8].…”
Section: Introductionmentioning
confidence: 99%
“…Surface plasmon excitation in the infrared region involves the use of chalcogenide 5 and silicon as coupling prism materials. 19,20 Gupta et al have worked on tuning and sensitivity enhancement of an SPR sensor. A work on modeling of chalcogenide glass based SPR sensor for chemical sensing using near-infrared light has been reported earlier.…”
Section: Introductionmentioning
confidence: 99%