2010
DOI: 10.1016/s0022-3913(10)60098-4
|View full text |Cite
|
Sign up to set email alerts
|

Effect of pretest storage conditions of extracted teeth on their dentin bond strengths

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
20
0
6

Year Published

2014
2014
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(26 citation statements)
references
References 28 publications
0
20
0
6
Order By: Relevance
“…[49] recommended use of frozen teeth at −20 o C or storage of teeth in 1% chloramine at 4 o C. Before using any teeth that were preserved in dry state, rehydration with distilled water for two weeks is recommended. [50]…”
Section: Variables Influencing Micro-bond Strength Test Resultsmentioning
confidence: 99%
“…[49] recommended use of frozen teeth at −20 o C or storage of teeth in 1% chloramine at 4 o C. Before using any teeth that were preserved in dry state, rehydration with distilled water for two weeks is recommended. [50]…”
Section: Variables Influencing Micro-bond Strength Test Resultsmentioning
confidence: 99%
“…Another limitation of this in vitro study is the use of storage solutions of thymol and chloramine T to store and disinfect teeth before manipulations. Although some study reported no significant effect on bond strength and micro microleakage leakage when using thymol and chloramine T [29][30][31] it has also been suggested that thymol, being a phenolic compound, may inhibit the polymerization of methyl methacrylate [40] and therefore may have influenced the results. Clinical limitations may also arise from a thick adhesive layer such as wear of the adhesive overtime and diagnostic issues if the particles are not radiopaque [11].…”
Section: Discussionmentioning
confidence: 99%
“…Teeth were first stored in a solution of 0.2% thymol until needed and subsequently cleaned and kept at 4 o C in a solution of 0.5% chloramine T for at least 24 h. Thymol and chloramine T were used in this study to store and disinfect teeth with minimal effect on tooth structures. These two storage media have been reported in the literature to have no significant effect on bond strength and microleakage [29][30][31]. Teeth were removed form the chloramine T and kept in artificial saliva throughout the study.…”
Section: Methodsmentioning
confidence: 99%
“…8 The collected teeth were stored in phosphate buffer saline containing 0.2% sodium azide at 48C for not more than two weeks until being used. 9 The study was accomplished in accord with local human participants' oversight committee guidelines.…”
Section: Specimen Preparationmentioning
confidence: 99%