1989
DOI: 10.1016/0039-9140(89)80232-2
|View full text |Cite
|
Sign up to set email alerts
|

Effect of photostability of mercury(II) dithizonate on photoacoustic spectroscopic determination of trace mercury

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

1997
1997
2007
2007

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 25 publications
0
4
0
Order By: Relevance
“…The second term in the above equation explains the dependence in [Fe(CN) 6 4-] at its low and high concentrations as exhibited by the rate dependence study on [Fe(CN) 6 4-] as shown in (FIG.4). When the large excess of [Fe(CN) 6 4-] is used, the equation (1) can be transformed to equation (2). (2) Where k′ corresponds to an experimental rate constant for an uncatalyzed path and K 2 ′ is a term for catalyzed path composed of many terms derivable from mechanistic scheme 30 respectively.…”
Section: Effect Of [Hg 2+ ]mentioning
confidence: 99%
See 1 more Smart Citation
“…The second term in the above equation explains the dependence in [Fe(CN) 6 4-] at its low and high concentrations as exhibited by the rate dependence study on [Fe(CN) 6 4-] as shown in (FIG.4). When the large excess of [Fe(CN) 6 4-] is used, the equation (1) can be transformed to equation (2). (2) Where k′ corresponds to an experimental rate constant for an uncatalyzed path and K 2 ′ is a term for catalyzed path composed of many terms derivable from mechanistic scheme 30 respectively.…”
Section: Effect Of [Hg 2+ ]mentioning
confidence: 99%
“…When the large excess of [Fe(CN) 6 4-] is used, the equation (1) can be transformed to equation (2). (2) Where k′ corresponds to an experimental rate constant for an uncatalyzed path and K 2 ′ is a term for catalyzed path composed of many terms derivable from mechanistic scheme 30 respectively. It is to be noted that absorbance values, A t (measured at t=15, 20 and 25 min.)…”
Section: Effect Of [Hg 2+ ]mentioning
confidence: 99%
“…Being toxic, it should be regularly monitored in a wide variety of samples such as air, water, soil, food, and human blood and urine. During the past decade, many new and improved methods for determination of mercury(II) have been developed and are listed in earlier reviews [1][2][3][4][5][6]. Many of these, however, lack sufficient sensitivity for determining mercury at subnanogram per milliliter levels.…”
Section: Introductionmentioning
confidence: 99%
“…techniques [2,7,8] are usually required prior to analysis, along with the disadvantage that a large volume of samples is required.…”
Section: Introductionmentioning
confidence: 99%