2015
DOI: 10.1016/j.jallcom.2014.08.125
|View full text |Cite
|
Sign up to set email alerts
|

Effect of partial substitution of silicon by other sp-valent elements on structure, magnetic properties and electrical resistivity of Co2FeSi Heusler alloys

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

5
8
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(15 citation statements)
references
References 34 publications
(45 reference statements)
5
8
1
Order By: Relevance
“…Cross-section SEM image of glass-coated microwire shown in Figure 1 wide plateau that corresponds to the glass-coating together with the crystalline patterns of the metallic nucleus corresponding to the B2 phase with a lattice parameter a = 5.615 Å, which is similar to the values presented in other works (5.66 Å) [13].…”
Section: Resultssupporting
confidence: 84%
See 2 more Smart Citations
“…Cross-section SEM image of glass-coated microwire shown in Figure 1 wide plateau that corresponds to the glass-coating together with the crystalline patterns of the metallic nucleus corresponding to the B2 phase with a lattice parameter a = 5.615 Å, which is similar to the values presented in other works (5.66 Å) [13].…”
Section: Resultssupporting
confidence: 84%
“…However, recent theoretical investigation on the spin polarization of fully ordered L2 1 and fully disordered B2 structure of Co 2 FeSi Heusler alloy reveals that both systems are half metallic. [2] Lately studies [13,[23][24][25][26] have shown that the half-metallic character and structural disorder of Heusler alloys can be predicted by simple electrical resistivity variation with temperature. In our case, the resistivity data was found to fit well with the relations presented in the published work by Bombor et al, [26].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…4) shows the ordinary ferromagnetic behavior -magnetization decreases with increase of temperature. The Curie temperature (T c ) of Co 2 FeSi Heusler ribbon was found to be about 1070 K and it corresponds well with the value from the literature [10]. [11].…”
Section: Resultssupporting
confidence: 85%
“…The mutual exchange between X and Y atoms positions of elements for the X 2 YZ Heusler alloy in L2 1 lattice can result in the DO3 disorder, which is difficult to detect by X-ray diffraction analysis with an ordinary Cu K α source alone. The lattice parameter of crystalline structure was estimated from the angle position of the Bragg peaks and their Miller index giving a value of a = 5.563 Å, which is similar to the lattice parameter for Co 2 FeSi alloy [11]. Figure 2 displays the thermomagnetic evolution of the Ni 2 FeSi alloy microwire from RT up to 1000 K (black curve) and cooling down (red curve), for the static magnetic field value of 100 Oe applied in the parallel direction with respect to the wire axis.…”
Section: Resultsmentioning
confidence: 99%