2016
DOI: 10.1016/j.ijcard.2016.01.048
|View full text |Cite
|
Sign up to set email alerts
|

Effect of oversizing and elliptical shape of aortic annulus on transcatheter valve hemodynamics: An in vitro study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
16
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 21 publications
(17 citation statements)
references
References 29 publications
1
16
0
Order By: Relevance
“…We observed that the aspect ratio of the annulus lumen increases during diastolic phases and decreases during the systolic phases (10% to 30%). The largest difference was between 10% and 70%, which confirms previous findings [ 24 , 34 ] that the annulus remains elliptical during the whole cardiac cycle.…”
Section: Discussionsupporting
confidence: 91%
“…We observed that the aspect ratio of the annulus lumen increases during diastolic phases and decreases during the systolic phases (10% to 30%). The largest difference was between 10% and 70%, which confirms previous findings [ 24 , 34 ] that the annulus remains elliptical during the whole cardiac cycle.…”
Section: Discussionsupporting
confidence: 91%
“…To our best knowledge, this study is the first to systematically analyze the impact of abnormal TAV deployment on the valve hemodynamics using an integrated computational and experimental approach. Although the effect of ellipticity and under‐expanded deployment of TAVs on valvular hemodynamics has been studied previously by in vitro experiments , some of these studies have shown contradictory results due to the lack of parametric control. A study found that the circular valve had a lower mean TPG compared with the elliptical valve for the test condition of 5 L/min CO (6.9 vs. 8.0 mm Hg).…”
Section: Discussionmentioning
confidence: 99%
“…Again, our results agree with the experimental observations. Salaun et al investigated the effect of oversizing and elliptical shape on Edwards SAPIEN valves. They found that for a given aortic annulus area, mean TPGs were generally lower with elliptical annuli compared to circular annuli.…”
Section: Discussionmentioning
confidence: 99%
“…The annuli tested in this study had "ideal circular contours". In vivo, bicuspid valve phenotype and presence of calcification nodules at the level of aortic annulus often yields to non-circular [29] and irregular annulus cross-sectional shape, which may be associated with increased leaflet mechanical stress, and therefore reduced long-term durability of the TAV. In addition, the CoreValve was tested only in the supra-annular position as recommended clinically, and not in intra-annular or high supra-annular position, which could also have an effect on the valve deployment and the leaflet bending stress.…”
Section: Study Limitationsmentioning
confidence: 99%