2018
DOI: 10.1007/s00289-018-2272-7
|View full text |Cite|
|
Sign up to set email alerts
|

Effect of operating pressure and pyrolysis conditions on the performance of carbon membranes for CO2/CH4 and O2/N2 separation derived from polybenzimidazole/Matrimid and UIP-S precursor blends

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
4
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1
1

Relationship

2
7

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 50 publications
0
4
0
Order By: Relevance
“…As can be seen, the fitted regression line was obtained with an R 2 value greater than 0.99. A value above R 2 indicates a proper fit of the regression line and the calibration curve [ 45 ].…”
Section: Resultsmentioning
confidence: 99%
“…As can be seen, the fitted regression line was obtained with an R 2 value greater than 0.99. A value above R 2 indicates a proper fit of the regression line and the calibration curve [ 45 ].…”
Section: Resultsmentioning
confidence: 99%
“…(a) Plot of CO 2 /CH 4 selectivity versus CO 2 permeability for a 21-day-aged 40 wt/wt MOP-18/PIM-1 CMSM (red box solid), alongside CMSMs reported in the literature on Robeson’s CO 2 /CH 4 upper bound . PBI/Matrimid (pink triangle up solid), PBI/UIP-S (blue circle open), P84 (purple circle solid), 6FDA/PMDA-TMMDA (yellow tilted square solid), and PIM-PI (green tilted square open) . (b) Plot of CO 2 /CH 4 selectivity versus CO 2 permeability for fresh (■) and aged (red box) 40 wt/wt MOP-18/PIM-1 CMSMs alongside fresh (▲) and aged (red triangle up open) PIM-1-derived CMSMs.…”
Section: Resultsmentioning
confidence: 99%
“…These days, membrane technologies have vastly come into consideration for several reasons such as low energy consumption, the low volume of modules, the possibility and availability, without thermal sensitivity, the very negligible pressure drop, low energy loss and low investment costs in comparison with other separation methods [1][2][3][4][5][6]. Regardless of the fact that membrane technologies have remarkable advantages in comparison with other separation methods, membrane processes are mainly dealt with several problems such as concentration polarization, blockage, not predicting the proper behavior of the membrane, stability, incomplete separation, puri cation and low permeability [7][8][9][10][11][12][13].…”
Section: Introductionmentioning
confidence: 99%