2015
DOI: 10.5812/iranjradiol.25272
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Object Position in Cone Beam Computed Tomography Field of View for Detection of Root Fractures in Teeth with Intra-Canal Posts

Abstract: Background:Vertical root fracture (VRF) is a common problem in endodontically treated teeth. Due to its poor prognosis, a reliable technique must be used to make an accurate diagnosis. Cone beam computed tomography (CBCT) has been recently introduced for maxillofacial imaging. Despite the high diagnostic value of this method, metal artifacts resulting from intra-canal posts still make the detection of VRFs challenging.Objectives:This study aimed to assess the effect of object position in the field of view (FOV… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
6
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 29 publications
2
6
0
Order By: Relevance
“…Although Rabelo et al 19 observed that variations of mA and kV do not affect the quantification of artefacts in CBCT images with different intracanal filling materials, it is important to note that other factors may affect artefact formation, such as voxel size, slice thickness and FOV size. 7 Therefore, it is necessary to develop future in vitro studies that take these variables into account when counting the artefacts generated by implants. Moreover, it is essential to develop research that associates the number of artefacts with diagnostic accuracy to ascertain the real level of interference of these unwanted images on clinical dental practice.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Although Rabelo et al 19 observed that variations of mA and kV do not affect the quantification of artefacts in CBCT images with different intracanal filling materials, it is important to note that other factors may affect artefact formation, such as voxel size, slice thickness and FOV size. 7 Therefore, it is necessary to develop future in vitro studies that take these variables into account when counting the artefacts generated by implants. Moreover, it is essential to develop research that associates the number of artefacts with diagnostic accuracy to ascertain the real level of interference of these unwanted images on clinical dental practice.…”
Section: Discussionmentioning
confidence: 99%
“…3,4 Cone beam CT (CBCT) has become the most widely used examination in implantology, as it minimizes the limitations of two-dimensional images. [4][5][6][7] Owing to its capacity to provide three-dimensional information, CBCT provides high image quality, diagnostic accuracy and linear measurement precision, thus increasing dental implant installation safety and treatment success rates. 2,3,[5][6][7][8][9] However, in the post-surgical follow-up phase, metal artefacts form inside the field of view (FOV), affecting tomographic image quality, [1][2][3][4][5][6][9][10][11] affecting, e.g.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…InStat (Windows version, GraphPad Software, CA, USA ) was used for statistical analysis of the study. Wilcoxon test 22 following Tukey post hoc test (considering critical value q > 4.418 as significant) 23 was performed for predictive values between the 4 diagnostic modalities. The results were considered significant at a 99% confidence level.…”
Section: Methodsmentioning
confidence: 99%
“…They concluded that the center-scanned position was found to be the only position that had reliable sensitivity for detecting VRFs. [ 22 ] Moreover, note that advances in radiology must also be accompanied by advanced user-level expertise with the specific diagnostic task.…”
Section: Methodsmentioning
confidence: 99%