2012
DOI: 10.1016/j.ijheatmasstransfer.2011.09.064
|View full text |Cite
|
Sign up to set email alerts
|

Effect of number of tube rows on the air-side performance of crimped spiral fin-and-tube heat exchanger with a multipass parallel and counter cross-flow configuration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
10
0
1

Year Published

2014
2014
2022
2022

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 65 publications
(12 citation statements)
references
References 16 publications
1
10
0
1
Order By: Relevance
“…6. The j-Colburn factor and f-friction factor of serrated welded spiral fin-and-tube heat exchanger at fin pitch of 4.2 mm in this study are compared with Pongsoi et al [12] (for crimped spiral fin), Pongsoi et al [15] (for L-footed spiral fin), Wang and Chang [28] and Wang et al [29] (for plain fin), and Briggs and Young [30] and Robinson and Briggs [31] (for circular fin) correlations, as shown in Fig. 6(a) (for j-Colburn factor) and Fig.…”
Section: Reynolds Number (Rementioning
confidence: 87%
See 3 more Smart Citations
“…6. The j-Colburn factor and f-friction factor of serrated welded spiral fin-and-tube heat exchanger at fin pitch of 4.2 mm in this study are compared with Pongsoi et al [12] (for crimped spiral fin), Pongsoi et al [15] (for L-footed spiral fin), Wang and Chang [28] and Wang et al [29] (for plain fin), and Briggs and Young [30] and Robinson and Briggs [31] (for circular fin) correlations, as shown in Fig. 6(a) (for j-Colburn factor) and Fig.…”
Section: Reynolds Number (Rementioning
confidence: 87%
“…In this study, the serrated welded spiral fin-and-tube heat exchangers having Z-shape tube arrangements and the 2 tube rows are investigated by using the experimental apparatus of Pongsoi et al [11][12][13][14][15] and Pongsoi and Wongwises [16], including the water flow loop, air-flow supply, measuring instruments, and data acquisition. The detailed geometrical parameters of the test sections are shown according to Table 1.…”
Section: Data Reductionmentioning
confidence: 99%
See 2 more Smart Citations
“…The effect remains similar even for finned tube heat exchanger with larger fin pitches [6]. On the other hand, Pongsoi et al [7] found an insignificant effect of the number of tube rows at high Reynolds numbers (4000-13,000) for crimped spiral finned tube heat exchangers. Similarly, Tang [8] investigated finned tube heat exchangers having larger tube diameters with different fin configurations (plain fins, slit fins and delta wing vortex generators).…”
Section: Introductionmentioning
confidence: 97%