2015
DOI: 10.1371/journal.pone.0139541
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Misalignment between Successive Corneal Videokeratography Maps on the Repeatability of Topography Data

Abstract: PurposeTo improve the reliability of corneal topographic data through the development of a method to estimate the magnitude of misalignment between successive corneal videokeratography (VK) maps and eliminate the effect of misalignment on the repeatability of topography data.MethodsAnterior and posterior topography maps were recorded twice for 124 healthy eyes of 124 participants using a Pentacam, and the repeatability of measurements was assessed by calculating the differences in elevation between each two se… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

2017
2017
2019
2019

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(16 citation statements)
references
References 24 publications
0
16
0
Order By: Relevance
“…In this study, an ICP algorithm, developed in earlier work 10 was used to estimate misalignment between each two successive tomography measurements. Correction for the small misalignments detected resulted in significantly reduced matching errors between successive maps from 18.43 ± 21.54 μm to 6.35 ± 4.58 μm (p < 0.01) in anterior KC maps and from 29.53 ± 24.62 μm to 19.62 ± 11.79 μm (p < 0.01) in posterior KC maps.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In this study, an ICP algorithm, developed in earlier work 10 was used to estimate misalignment between each two successive tomography measurements. Correction for the small misalignments detected resulted in significantly reduced matching errors between successive maps from 18.43 ± 21.54 μm to 6.35 ± 4.58 μm (p < 0.01) in anterior KC maps and from 29.53 ± 24.62 μm to 19.62 ± 11.79 μm (p < 0.01) in posterior KC maps.…”
Section: Discussionmentioning
confidence: 99%
“…The device was moved back and realigned again after finishing each acquisition. Tomography measurements were taken by the same trained examiner (LFH), while the details were described in previous studies 10 , 32 . All methods were performed in accordance with the relevant guidelines and regulations.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The ICP algorithm has been a dominant method for registration of 3D free-form surfaces, and was introduced successfully to match topography maps in a rapid process (within 1 to 2 seconds) 3234 .…”
Section: Discussionmentioning
confidence: 99%
“…Since using six independent misalignment components makes it challenging to have an overall impression of correlation between misalignment and data repeatability, CM was developed to combine their individual effects on data repeatability 32 . RMS should be zero if the second successive measurements matched perfectly with the first, however, this is unlikely to occur in all cases.…”
Section: Methodsmentioning
confidence: 99%