2014
DOI: 10.1016/j.corsci.2014.03.018
|View full text |Cite
|
Sign up to set email alerts
|

Effect of marine Pseudoalteromonas sp. on the microstructure and corrosion behaviour of 2205 duplex stainless steel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
24
0
1

Year Published

2014
2014
2018
2018

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 83 publications
(28 citation statements)
references
References 31 publications
3
24
0
1
Order By: Relevance
“…Liu (2014) found that the 2205 DSS was susceptible to MIC, and the 2205 DSS pipe on board a new yacht failed due to an extremely high corrosion rate (40 mm year −1 ). Moradi et al (2014) found that a high concentration of chloride ion was present in the biofilm structure, leading to a loss of the amount of Cr in 2205 DSS underneath the biofilm and causing pitting corrosion.…”
Section: Introductionmentioning
confidence: 98%
See 1 more Smart Citation
“…Liu (2014) found that the 2205 DSS was susceptible to MIC, and the 2205 DSS pipe on board a new yacht failed due to an extremely high corrosion rate (40 mm year −1 ). Moradi et al (2014) found that a high concentration of chloride ion was present in the biofilm structure, leading to a loss of the amount of Cr in 2205 DSS underneath the biofilm and causing pitting corrosion.…”
Section: Introductionmentioning
confidence: 98%
“…For a super duplex SS (SDSS), the value of PREN is up to 40-45 (Elhoud et al 2010). When exposed to the marine environment, in spite of its high PREN value, DSS still suffers from severe localized corrosion, such as the pitting corrosion caused by microorganisms, known as microbiologically influenced corrosion (MIC) (Moradi et al 2014). Liu (2014) found that the 2205 DSS was susceptible to MIC, and the 2205 DSS pipe on board a new yacht failed due to an extremely high corrosion rate (40 mm year −1 ).…”
Section: Introductionmentioning
confidence: 99%
“…Several mechanisms and models have been proposed for interpreting impedance spectra on a passive metal surface . The model of Figure was selected to fit the experiment, assuming that the passive film did not totally cover the metal and cannot be considered as a homogeneous layer but rather as a defective layer.…”
Section: Resultsmentioning
confidence: 99%
“…EIS measurements were used to evaluate how the biofilms influenced the corrosion rate of steel in different corrosion media [16]. Fig.5 shows the EIS results of specimens exposed to different systems.…”
Section: Electrochemical Impedance Measurementsmentioning
confidence: 99%