Abstract:In a lab-scale bioreactor system, (20 L of effective volume in our study) controlling a constant temperature inside bioreactor with a total volume 25 L is a simple process, whereas it is a complicated process in the actual full-scale system. There might exist a localized temperature difference inside the reactor, affecting bioenergy yield. In the present work, the temperature at the middle layer of bioreactor was controlled at 35 °C, while the temperature at top and bottom of bioreactor was controlled at 35 ± … Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.