2011 Third International Conference on Computational Intelligence, Modelling &Amp; Simulation 2011
DOI: 10.1109/cimsim.2011.78
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Load Variations in DC-DC Converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 7 publications
0
4
0
Order By: Relevance
“…Current-mode control is one of the major control methods that is widely used in the topology of most Buck converters [27,28]. This technique has proven its vibrant performance and undeniable properties such as protection of short circuits [29]. Current-mode control has two major types: peak current-mode control and average current-mode control.…”
Section: Proposed Feedback Pid Control Schemementioning
confidence: 99%
“…Current-mode control is one of the major control methods that is widely used in the topology of most Buck converters [27,28]. This technique has proven its vibrant performance and undeniable properties such as protection of short circuits [29]. Current-mode control has two major types: peak current-mode control and average current-mode control.…”
Section: Proposed Feedback Pid Control Schemementioning
confidence: 99%
“…The closed-loop voltage gain, G can be derived from Figure 5 using the reduction block method. By setting io to be 0, and the model can be simplified to (7). By setting vi* to 0, the model can be simplified to (8) to find the output impedance of the inverter…”
Section: Generalized Model Of Single-phase Invertermentioning
confidence: 99%
“…Whenever the operation of microgrid shifted to island mode, electric potential, E and frequency,  are considered to be maintained with several inverters working in parallel and sharing the load. These inverters act in regulating the voltage; amplitude and frequency, instead of different mode of operation like other converter [7]; besides providing the required current needed. However, the issue of power quality [8] that contributed by the existence of transient circulating current in line impedance [9] will lead to the system instability, thus can harmful the inverters [10] due to mismatch of the output voltage.…”
mentioning
confidence: 99%
“…A number of works have been devoted to the simulation of DC-DC converters and therefore the simulations are not described in detail here, only the results are given [11][12][13][14][15]. Simulations were performed in SPICE and partly confirmed by Simulink.…”
Section: Introductionmentioning
confidence: 99%