2017
DOI: 10.1016/j.prosdent.2016.07.024
|View full text |Cite
|
Sign up to set email alerts
|

Effect of internal hexagonal index on removal torque and tensile removal force of different Morse taper connection abutments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
23
0
6

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(32 citation statements)
references
References 24 publications
3
23
0
6
Order By: Relevance
“…Various methods, such as insertion torque, removal torque, histomorphometric analysis, Periotest, percussion test, and resonance frequency analysis (RFA) have been used to assess implant stability . However, standardized methods to evaluate and monitor implant stability are yet to be determined.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Various methods, such as insertion torque, removal torque, histomorphometric analysis, Periotest, percussion test, and resonance frequency analysis (RFA) have been used to assess implant stability . However, standardized methods to evaluate and monitor implant stability are yet to be determined.…”
Section: Introductionmentioning
confidence: 99%
“…3 Various methods, such as insertion torque, removal torque, histomorphometric analysis, Periotest, percussion test, and resonance frequency analysis (RFA) have been used to assess implant stability. [13][14][15][16][17][18] However, standardized methods to evaluate and monitor implant stability are yet to be determined. The OSSTELL (Osstell, Gothenburg, Sweden) was developed nearly two decades ago in which, a transducer is attached to the implant, that is, excited by an electric or magnetic impulse generated by the device.…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, dental implants with Morse taper connection or internal hex connection showed similar failure rate 10 . Since these two types of connection designs have their own advantages and disadvantages, recently, manufacturers combined these two types of connection designs and came up with internal hex combined with Morse taper design 11 , 12 . Hopefully, this new design can combine the benefits of internal hex and Morse taper designs.…”
Section: Discussionmentioning
confidence: 99%
“…Apesar da alta taxa de sucesso dos implantes osseointegráveis, ainda nos deparamos no dia a dia clínico com casos de insucesso, principalmente devidos a complicações biológicas, sobrecarga oclusal, número inadequado de implantes, ausência de passividade, micromovimentação, presença de microgaps, escolha inadequada do componente protético, fratura do implante ou componente, pré-carga e afrouxamento do parafuso de retenção (Branemark et al, 1977;Misch et al, 2005;Heitz-Mayfield, 2008;Shin et al, 2014;Lee et al, 2016;De Oliveira Silva et al, 2017;Elsayed et al, 2018).…”
Section: Perda De Torqueunclassified
“…A pré-carga é influenciada pelas propriedades físicas dos parafusos de retenção, como design e dimensões, atrito entre as superfícies, torque de inserção adequado e ciclos de aperto/afrouxamento (De Oliveira Silva et al, 2017;Xia et al, 2014;Bernardes et al, 2014).…”
unclassified