1979
DOI: 10.1002/jps.2600681043
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Instrumental Vibration Levels on Dissolution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
5
0

Year Published

1979
1979
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 4 publications
0
5
0
Order By: Relevance
“…Embil and Torosian had studied vibration effects on drug release of enteric-coated aspirin tablets in the paddle apparatus [9]. Similar to Beyer and Smith, they observed a more pronounced vibration effect resulting in a decrease in dissolution times at low paddle speeds (50 rpm) which could be overcome by increasing the paddle speed to 200 rpm.…”
Section: Introductionmentioning
confidence: 84%
“…Embil and Torosian had studied vibration effects on drug release of enteric-coated aspirin tablets in the paddle apparatus [9]. Similar to Beyer and Smith, they observed a more pronounced vibration effect resulting in a decrease in dissolution times at low paddle speeds (50 rpm) which could be overcome by increasing the paddle speed to 200 rpm.…”
Section: Introductionmentioning
confidence: 84%
“…[49] Moreover, vibration and agitation speeds are reported to enhance drug dissolution and delivery. [50][51][52] Seeger et al analyzed and tested the early studies conducted by Beyer and Smith on the dissolution rate of tolbutamide (used for the treatment of non-insulin-dependent diabetes mellitus), [53] and the Embil and Torosian studies on enteric-coated aspirin, [54] and confirmed the strong effects of increasing vibration on the drug dissolution time at a low agitation speed of 50 rpm. [50] Liu et al studied the impact of vibration at 3200, 4800, and 6400 rpm on drug dissolution.…”
Section: Introductionmentioning
confidence: 99%
“…[ 50–52 ] Seeger et al. analyzed and tested the early studies conducted by Beyer and Smith on the dissolution rate of tolbutamide (used for the treatment of non‐insulin‐dependent diabetes mellitus), [ 53 ] and the Embil and Torosian studies on enteric‐coated aspirin, [ 54 ] and confirmed the strong effects of increasing vibration on the drug dissolution time at a low agitation speed of 50 rpm. [ 50 ] Liu et al.…”
Section: Introductionmentioning
confidence: 99%
“…were matched in their performance using a single batch of tablets and modified to reduce unwanted vibrations by the incorporation of a 1000-pF capacitor in the speed control circuit (5).…”
mentioning
confidence: 99%
“…The dissolution vessel was a 900-ml round-bottom resin flask fitted with an appropriate glass cup. Two dissolution apparatus, designated left (L) and right (R), were matched in their performance using a single batch of tablets and modified to reduce unwanted vibrations by the incorporation of a 1000-pF capacitor in the speed control circuit (5).…”
mentioning
confidence: 99%