2020
DOI: 10.1016/j.ajem.2019.01.050
|View full text |Cite
|
Sign up to set email alerts
|

Effect of insonation angle on peak systolic velocity variation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…A 2019 study by Radparvar et al, highlights the importance of the angle of insonation when measuring carotid DVpeak. 26 They demonstrated that a more oblique probe position on a participant's neck produced more precise results. Specifically, as the angle of insonation was increased from 46 to 90 the standard error of the carotid DVpeak increased from 6% to 14%.…”
Section: Discussionmentioning
confidence: 99%
“…A 2019 study by Radparvar et al, highlights the importance of the angle of insonation when measuring carotid DVpeak. 26 They demonstrated that a more oblique probe position on a participant's neck produced more precise results. Specifically, as the angle of insonation was increased from 46 to 90 the standard error of the carotid DVpeak increased from 6% to 14%.…”
Section: Discussionmentioning
confidence: 99%
“…As a result, both manual and automatic cardiac output measurements had poor accuracy compared to the standardized control. Measurement variation likely has multiple sources, including human factors [ 16 , 17 ], ultrasound factors [ 18 ], and intrinsic fluctuation secondary to patient physiology (e.g., respiratory variation). However, ultrasound and patient factors were less likely to contribute to measurement variability in our study since trainees and expert echocardiographers used the same machines and obtained measurements from only one patient.…”
Section: Discussionmentioning
confidence: 99%
“…Future algorithms could guide the sonographer towards correct placing and setting of the US probe, improving reliability and repeatability of measurements. Furthermore, the development of wearable devices will likely mitigate the effect of insonation angle (Radparvar et al 2020), minimize positioning errors and allow continuous measurement. Lui et al (Lui et al 2005) found no significant difference between manual velocity measurements and those obtained with an automatic peak velocity tracker.…”
Section: Automating Cdumentioning
confidence: 99%