2022
DOI: 10.1016/j.applthermaleng.2021.117625
|View full text |Cite
|
Sign up to set email alerts
|

Effect of inclination angle on the startup of a frozen sodium heat pipe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 41 publications
(9 citation statements)
references
References 37 publications
0
5
0
Order By: Relevance
“…The results show that the moderation of the core can decrease the maximum neutron flux and is beneficial to reducing the thickness and weight of the shield. In addition, many studies (Ma et al, 2020a;Ma et al, 2021b;Ma et al, 2022a;Ma et al, 2022b) focused on thermal-hydraulic analyses of the Megapower. In order to improve the power output of the reactor, Westinghouse Electric Company (2017) proposed a 15 MWe eVinci reactor with UN fuel, which can operate for more than 10 years without refueling.…”
Section: Resultsmentioning
confidence: 99%
“…The results show that the moderation of the core can decrease the maximum neutron flux and is beneficial to reducing the thickness and weight of the shield. In addition, many studies (Ma et al, 2020a;Ma et al, 2021b;Ma et al, 2022a;Ma et al, 2022b) focused on thermal-hydraulic analyses of the Megapower. In order to improve the power output of the reactor, Westinghouse Electric Company (2017) proposed a 15 MWe eVinci reactor with UN fuel, which can operate for more than 10 years without refueling.…”
Section: Resultsmentioning
confidence: 99%
“…By the capillary force generated in the wick structure, the working medium is driven from the evaporator section back to the condenser section, which could provide a very high value of equivalent thermal conductivity of up to 100000 W/mꞏK considering its lightweight and small size, thereby making it a competitive cooling device for electrical machines [9]. Due to the gravitational effect on the backflow of the working medium, the inclination angle has a significant impact on HP thermal performance, which has been confirmed by the studies in the fields of thermology and mechanical engineering [11][12][13][14][15][16]. If we define the inclination angle θ as the angle between the backflow direction and the gravity direction of the working medium, the gravitational effect on the backflow of the internal working medium in the HP can be divided into the gravity-assisted case (θ<90 °) and gravity-opposed case (θ >90 °), as shown in Fig.…”
Section: Introductionmentioning
confidence: 86%
“…Heat pipe experiments usually focus on the investigation of operating limits [33][34][35][36][37][38], wick development and performance [39], startup transients [40,41], inclination angles [42][43][44], novel instrumentation [16,40,45], two-phase flow characteristics [46], and motion conditions [47]. This subsection discusses some of these different experimental approaches.…”
Section: Heat Pipe Experimental Methodsmentioning
confidence: 99%
“…Examples of transients include liquid metal heat pipe frozen startup, power transients during normal operation, recovery from heat pipe limit, the cascading failure of multiple heat pipes, and system level transients. Many works have investigated heat pipe response to changes in evaporator input power or condenser cooling rates [58][59][60], to transients in systems with heat pipes as components [61,62], and heat pipe startup [40,42,[63][64][65].…”
Section: Steady State and Transientsmentioning
confidence: 99%