2007
DOI: 10.1016/j.corsci.2007.03.038
|View full text |Cite
|
Sign up to set email alerts
|

Effect of hydrogen on the fracture behavior of high strength steel during slow strain rate test

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

9
151
0
8

Year Published

2012
2012
2024
2024

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 354 publications
(168 citation statements)
references
References 24 publications
9
151
0
8
Order By: Relevance
“…Hot extraction experiments were performed using a G8 Galileo with Thermal Conductivity Detector (TCD) from Bruker (Bruker, Karlsruhe, Germany) at 300 • C to determine the amount of diffusible hydrogen, according to the definition for diffusible hydrogen, as proposed by Wang et al [22], and frequently applied since [23]. After extracting the samples from the vessel, they were stored in liquid nitrogen to minimise the loss of hydrogen.…”
Section: Methodsmentioning
confidence: 99%
“…Hot extraction experiments were performed using a G8 Galileo with Thermal Conductivity Detector (TCD) from Bruker (Bruker, Karlsruhe, Germany) at 300 • C to determine the amount of diffusible hydrogen, according to the definition for diffusible hydrogen, as proposed by Wang et al [22], and frequently applied since [23]. After extracting the samples from the vessel, they were stored in liquid nitrogen to minimise the loss of hydrogen.…”
Section: Methodsmentioning
confidence: 99%
“…[44][45][46][47][48][49]65) Slow strain rate test (SSRT) was performed using CNRB- The maximum value of HE measured after SSRT of exposed notched bar specimens was used as HE of B15, B13 and A13. The maximum HE of exposed bolt was used as HE of A11.…”
Section: B15 > B13 > A13 > A11mentioning
confidence: 99%
“…41) They also obtained critical NTS for delayed fracture by increasing applied stress in stepwise manner to obtain shape parameter in Weibull stress for evaluation of delayed fracture. 42 43) and the present authors [44][45][46][47][48][49] carried out slow strain rate test (SSRT) of hydrogen-precharged CNRBSs, and obtained the relationship between NTS and hydrogen content. For convenience and simplification, Hagihara et al proposed Conventional Strain Rate Test (CSRT) with a strain rate which is 2 orders of magnitude higher than that of SSRT.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, susceptibility to delayed fracture is evaluated by Slow Strain Rate Test (SSRT) [6][7][8][9][10][11][12] and Conventional Strain Rate Test (CSRT) [13][14][15][16] which can complete the delayed fracture test in a shorter time than CLT. The relationship between H C and fracture stress can be obtained by SSRT and CSRT.…”
Section: )mentioning
confidence: 99%